PCB-3503A1060KG

PCB-3503A1060KG

  • Triaxial MEMS high-shock sensor,
  • Measuring range 60,000 g,
  • Sensitivity 0.0003 mV / V / g,
  • Frequency range 0 … 10,000 Hz,
  • Integrated cable, length 3 m,
    ending on stripped and tinned ends
  • basic data
    sensitivity (at 10 V DC supply voltage) (±50%)0.003 mV / g0.0003 mV/(m/s²)[1]
     
    sensitivity0.0003 mV / V / g0,00003 mV/V/(m/s²)[7]
     
    Range±60. 000 g±588. 400 m/s² pk 
     
    frequency range (1 dB)0 … 10,000 Hz  
     
    Resonance frequency? 120,000 Hz  
     
    damping rate2% crit chance [3]
     
    Linearity error≤1%  
     
    transverse acceleration sensitivity≤ 3  
    conditions
    Overload limit (Shock)±80. 000 g pk±784. 532 m/s² pk[2]
     
    Overload limit (mechanical stop)≥80,000 g? 782.534 m/s² pk 
     
    temperature range (storage)-65 … 250 ° F-54 … 121 ° C 
     
    temperature range (operation)-65 … 250 ° F-54 … 121 ° C 
     
    Temperature coefficient of sensitivity-0.11 %/°F-0.20 %/°C[3]
     
    Max thermal offset shift±10 mV [4]
     
    Strain sensitivity (base area)0,3 g/µε2.94 (m/s²)/µε[3]
    specifications
    power supply voltage (max)15.0 V DC  
     
    power< 12 mA  
     
    input resistance (±700 Ω)2,000Ω [1]
     
    output impedance (kΩ ±2)6,000Ω [1]
     
    Spannungsoffset40 … 40 mV DC [1]
     
    settling time0.01 s [5]
     
    electrical insulation (housing)≥100 MΩ [6]
    PhysicalProperties
    sensor elementPiezoresistive MEMS element  
     
    geometry of the sensor elementActive bridge circuit  
     
    Housing materialtitanium  
     
    waterproofingepoxy resin  
     
    size - height0.25 in6.35 mm 
     
    size - length0.47 in11.81 mm 
     
    size - width0.47 in11.81 mm 
     
    Dimensions (without cable)0.1 oz2.83 grams[3]
     
    electrical connectionintegrated cable  
     
    connection positionSide  
     
    cord typetype 026, 8-conductor shielded PTFE cable  
     
    cable terminationtinned ends  
     
    Cable length10 ft3 m 
     
    mountingtwo mounting holes  
     
    Assembly torque8 in-lb  
    Notes
    [1]proSensor checked and documented on calibration certificate supplied with  
     
    [2]a half-sine pulse ≤ 20 µs  
     
    [3]Typically  
     
    [4]-54 … 121 ° C, reference 24 ° C  
     
    [5]settling time is the time the sensor signal maximum ben ötigt, after the supply voltage is applied the zero point on ±2% of the output span towards. The mounting surface must be located in the thermal balance.  
     
    [6]Pro sensor tested to ensure compliance with the specification  
     
    [7]Temperature coefficient of sensitivity is proportional to the applied supply voltage and can use a different voltage than at the calibration (10 V DC) are calculated from the calibration data. The possible measurement error increases with minimal (around0.5%).  
    Equipment
    081A114mounting screw and washer (4-40 x 3/8 "SHCS)2 
     
    ACS-62 TCalibration of Triaxial Piezoresistive shock sensors-1 

    1 other articles of the same category: