PCB-3501A1220KG

PCB-3501A1220KG

  • MEMS high shock sensor,
  • Measuring range 20,000 g
  • Sensitivity 0.001 mV / V / g,
  • Frequency range 0 … 10,000 Hz,
  • Integrated cable, length 3 m,
    ending on stripped and tinned ends
  • basic data
    sensitivity (at 10 V DC supply voltage) (±50%)0.010 mV / g0.001 mV/(m/s²)[1]
     
    sensitivity0.001 mV / V / g0.0001 mV/V/(m/s²) 
     
    range±20. 000 g±196.100 m/s² pk 
     
    Frequency range (1 dB)0 … 10,000 Hz  
     
    resonance frequency> 60,000 Hz  
     
    damping rate5% critical [4]
     
    linearity≤1%  
     
    transverse acceleration sensitivity≤3%  
    Conditions of use
    Overload limit (shock)±60. 000 g pk±588. 000 m/s² pk[2] [3]
     
    Overload limit (mechanical stop)≥30,000 g≥294.200 m/s² pk 
     
    temperature range (operation)65 …250 ° F-54 … 121 ° C 
     
    Temperature coefficient of sensitivity-0.11 %/°F-0.20 %/°C[4]
     
    maximum thermal Offset offset±10 mV [5]
     
    strain sensitivity (footprint)0.10 g/µε0.98 (m/s²)/µε[4]
     
    Magnetic sensitivity10µg/Gs/0.98 (m/s²) / T[4]
    technical characteristics
    supply voltage (max)15.0 V DC  
     
    Power< 3 mA  
     
    input impedance (kΩ ±2)6,000Ω [1]
     
    Output impedance (±2 k Ω)6,000Ω [1]
     
    Spannungsoffset40 … 40 mV DC [1]
     
    settling time0.01 s [6]
     
    electrical insulation (housing)≥100 MΩ [3]
    physical properties
    Sensor elementPiezoresistive MEMS element  
     
    geometry of the sensor elementActive bridge circuit  
     
    go äusematerialtitanium  
     
    waterproofingepoxy resin  
     
    size - hex3/8 in9.5 mm 
     
    Size - height0.50 in12.7 mm 
     
    dimensions (without cable)0.088 oz2.5 grams[4]
     
    Electrical connectionintegrated cable  
     
    connection positionside  
     
    cable typetype 034, 4-conductor shielded cable  
     
    Cable terminationtinned ends  
     
    cable length10 ft3 m 
     
    mountingFixed external thread  
     
    mounting thread1/4 "-28 thread  
    notes
    [1]gepr Pro sensor" üft and documents calibration certificate supplied with  
     
    [2]perioda half-sine pulse, ≤ 20 µs  
     
    [3]Pro sensor tested to ensure compliance with the specification  
     
    [4]Typically  
     
    [5]-54 … 121 ° C, reference 24 ° C  
     
    [6]settling time is the time the the Sensor signal maximum needed to relax after the supply voltage is applied the zero point on ±2% of the output span towards. The mounting surface must be located in the thermal balance.  
    Accessories
    ACS-62calibration of Piezoresistive shock sensors-1 
    (M) metric mounting
    mounting threadM6 x 0.75 male  

    3 other articles of the same category: