PCB-130A23
    zoom_out_map

      PCB-130A23

    • ICP® array free field microphone,
    • With TEDS 1.0,
    • Diameter 7 mm,
    • Sensitivity 14 mV / PA,
    • Dynamic range > 143 dB,
    • Frequency range 20 … 20,000 Hz,
    • SMB connector
    • basic data
      Nominal diameter of microphone1/4 "
      applicationfree-field
      Frequency range (±2 dB)20 … 20,000 Hz
      Live match (50 … 100 Hz)±5 °
      phase Compliance (100 … 3,000 Hz)±3 °
      Live match (3,000 … 5,000 Hz)±5 °
      Live match (5.000 …?10.000 Hz)±10 °
      Sensitivity (at 250 Hz)14 mV / PA
      (±3 dB) sensitivity (at 250 Hz)-37,1 dB in relation to 1 V / PA
      Noise (A-weighted)< 30 dB(A) in relation to 20 µPa
      dynamic range (maximum)150[1] [2]
      Dynamic range (for THD ≤ 3%)> 143 dB
      TEDS Chipintegrated by default[3]
      conditions
      temperature range (operation)14 … 122 ° F10 … 50 ° C
      influence of temperature on the output signal (-10 … 50 ° C)< 0.7 dB[2]
      influence by axial vibration (1 m/s²)60 dB in relation to 20 µPa[2]
      technical characteristics
      Power18 … 30 V DC
      constant power supply2 … 20 mA
      Bias voltage9 … 14 V DC
      output impedance< 52 Ω
      Physical properties
      Housing materialstainless steel
      Electrical connectionSMB coaxial socket
      size - diameter (total)0.28 in7.0 mm
      Gr öße - length (total)2.33 in59.1 mm
      mass0.26 oz7.4Gram[2]
      notes
      [1]clipping threshold
      [2]typically
      [3]TEDS memory in accordance with IEEE P1451. 4
      [4]details: see PCBs Declaration of conformance PS023
      Accessories
      ACS-21calibration of Electret microphone-1
      PCB-130A23

      Specific References

      Download

      130A23_drawing.PDF

      Technical drawing

      Download (279.21k)

      130A23_manual.PDF

      Operating instructions

      Download (793.13k)

      130A23_specs.PDF

      Technical data sheet

      Download (22.91k)