PCB-EX357E90

PCB-EX357E90

  • With ATEX / IECEx / CSA approval
  • Vibration sensor with charge output
  • Continuous operating temperature up to 649 ° C
  • With through hole
  • Measuring range 1,000 g
  • Sensitivity 5 pC / g
  • Upper limit frequency 2,500 Hz
  • Integrated hardline connection cable, length 3 meters,
    ending on 10-32 socket
  • New: slim 10-32 socket (diameter 6.35 mm)

specifications
basic dataEnglish unitsSI units 
Sensitivity (± 10%)5 pC/g0,51 pC/(m/s²)
measuring range± 1,000 g pk±9.800 m/s²pk
Upper cutoff frequency (± 5%)2.500 Hz
Upper limit frequency (± 1 dB)4.000 Hz
resonant frequency≥14.000 Hz
Linearity error (based on the entire measuring range)≤2,5 %
Lateral acceleration sensitivity≤5 %
Operating conditions
Overload limit (shock)± 2,000 g pk±19.600 m/s²pk
Temperature range (operation)-67 … 1.200 °F-55 … 649 °C
Temperature range (load limit)-67 … 1.400 °F-55 … 760 °C
Temperature range (connector)-67 … 900 °F-55 … 482 °C
Maximum radiation exposure (Integrated Neutron Flux)10.000.000.000 N/cm²
Maximum radiation exposure (Integrated Gamma Flux)100,000,000 rad
Maximum radiation conditions (ATEX approval)II 1 G Ex ia lIC T6… 770 ° C Ga
II 3 G Ex nA llC T6… 770 ° C Gc
0 ° C <Tamb <+755 ° C
Maximum radiation conditions (IECEx approval)Ex ia lIC T6 … 770 °C Ga
Ex nA llC T6 … 770 °C Gc
-55 °C < Tamb < +755 °C
Maximum radiation conditions (approval ELT)Class I, Division 1, Groups A-D
Class I, Zone 0, AEx ia IIC T6 … 770 °C Ga
Class I, Division 2, Group A, B, C, D
Class I, Zone 2, AEX nA IIC T6 … 770 °C Gc
-55 °C ≤ Tamb ≤ +755 °C
Technical characteristics
capacity990 pF[2][1]
Insulation resistance (at 649 ° C)≥10 kΩ
Insulation resistance (at 21 ° C)≥100 MΩ
Electrical insulationSignal isolated from the case
Physical properties
sensor elementUHT-12™
Geometry of the sensor elementScherprinzip
housing materialInconel
Sealing (sensor housing)Hermetically sealed
Sealing (connector)Hermetically sealed
Size - height0,66 in16,7 mm
Size - length1,16 in29,5 mm
Size - width0,66 in16,7 mm
Mass (without cable)1,8 oz50 grams[1]
Electrical connectionIntegrated hardline cable
cable length10 ft3 m
cable termination10-32 coaxial
attachmentThrough Hole

Hints
[1]typically,
[2]Plus approx. 330 pF per additional meter of cable

included supply
081C108Montageschraube, 1/4"-28 x 1" lang, Inconel(1)
ACS-1Frequency response, traceable to NIST (10 Hz to the upper 5% point)(1)

13 other articles of the same category: