PCB-66212APZ1

PCB-66212APZ1

  • ICP® vibration sensor for OEM applications,
  • TO-5 package,
  • Suitable for PCB mounting,
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 0.5 … 10,000 Hz,
  • One-point calibration at 100 Hz,
  • Connection pins below
  • basic data
    sensitivity (±20%)100 mV/g10.2 mV/(m/s²)[1] [2]
    measuring range50 Ω490 m/s²
    Frequency range (± 3 dB)0,5 … 10,000 Hz[3] [6]
    resonance frequency> 25,000 Hz[3]
    Wide band resolution350 µg RMS3.434 µm / s ² RMS[5]
    linearity error≤ 1%[4]
    transverse acceleration sensitivity≤ 7%
    conditions
    Overload limit (shock)5,000 g pk49,050 m/s² pk
    temperature range (operation)65 … 185 ° F-54 … 84 ° C
    technical characteristics
    settling time (on bias voltage ± 1%)≤ 2 s
    Discharge charge time constant≥ 0.3 s
    Power18 … 28 V DC
    constant power supply2 … 20 mA
    Output impedance< 150 Ω
    bias voltage (±10%)8 … 12 V DC
    Spectral noise (10 Hz)8 µg / √ Hz78,50 (µm / s ²) / √ Hz[5]
    spectral noise (100 Hz)5 µg /. √ Hz49,1 (µm / s ²) / √ Hz[5]
    spectral noise (1,000 Hz)4 µg / √ Hz39.2 (µm / s ²) / √ Hz[5]
    -physical Properties
    size - diameter of the footprint0.36 in9.1 mm
    size - height0.38 in9.7 mm
    Mass0.01 oz3 grams
    attachmentBonding/soldering
    sensor elementceramic
    Geometry of the sensor elementShear principle
    Housing materialstainless steel
    sealinghermetically sealed welded
    Electrical connectionssoldering pins
    Connectiondown
    pin assigNment (pin 1)Signal/power
    pin assigNment (pin 2) Mass
    pin assigNment (PIN 3)no function
    notes
    [1]conversion factor 1 g = 9.81 m/s²
    [2]positive output signal during acceleration in Z-direction < br(bei Lötmontage: positives Ausgangssignal bei Beschleunigung nach oben)
    [3] Depending on the installation
    [4]zero-based balancing line, determined using the method of least squares
    [5] Typically
    [6]the upper cut-off frequency tolerance: ±10%
    [7]details: see PCBs Declaration of conformance PS023 and PS060
    Accessories
    ICS-2single point calibration at 100 Hz (traceable to NIST)-1
    (HT) high temperature electronics
    temperature range (operation)-65 … 250 ° F-54 … 121 ° C

    1 other articles of the same category: