PCB-(M)350C04
    zoom_out_map

      PCB-(M)350C04

    • ICP® shock acceleration sensor,
    • With electric and mechanical filter,
    • Measuring range 5,000 g,
    • Sensitivity 1 mV / g,
    • Frequency range 0.4 … 10,000 Hz,
    • 10-32 female connector above
    • basic data
      sensitivity (±30%)1.0 mV / g0.10 mV/(m/s²) 
       
      range±5. 000 g pk±49. 000 m / pk 
       
      Frequency range (± 1 dB)0.4 … 10,000 Hz  
       
      frequency range (-3 dB)0.2 … 25,000 Hz [4]
       
      Corner frequency of the electrical filter (-3 dB)21,000 Hz [2] [1]
       
      resonance frequency of the mechanical filter35,000 Hz [3] [1]
       
      Resonance frequency≥ 100,000 Hz  
       
      wide band resolution (1 … 10,000 Hz)0.20 m/s² rmsrms 0.02 g[1]
       
      Linearity error≤ 2.0%  
       
      transverse acceleration sensitivity≤ 7%  
      conditions
      Overload limit (Shock)±50. 000 g pk±490. 000 m / pk 
       
      temperature range (operation)0 … 150 ° F-18 … 66 ° C 
       
      Temperature range(Storage)-40 …200 °F-40 … 93 ° C 
       
      Temperature influenceSee graph %/°F  
       
      strain sensitivity (footprint)0,002 g/µε0.02 (m/s²) /µε[1]
      specifications
      power supply20 … 30 V DC  
       
      Constant power supply2 … 20 mA  
       
      Output impedance≤200Ω  
       
      Bias voltage8 … 14 V DC  
       
      Discharging charging time constant1.0 … 2.0 s [1]
       
      settling time (area within ±10% of the bias voltage)< 10 s  
      Physical properties
      sensor elementceramic  
       
      geometry of the sensor elementshear principle  
       
      Housing materialtitanium  
       
      sealinghermetic  
       
      Size - hex0.375 in9.5 mm 
       
      size - height1.15 in29.2 mm 
       
      Mass0.19 oz5.4 grams[1]
       
      Electrical connection10-32-coaxial socket  
       
      connectiontop  
       
      mounting thread1/4 '28 External thread  
      notes
      [1]typically  
       
      [2]second-order low-pass filter  
       
      [3]the amplitude is increased in the resonance frequency by 9 dB.  
       
      [4]the specified upper limit frequency is a guideline. The frequency response is limited by the combination of electric and mechanical low pass filter.  
       
      [5]details: see PCBs Declaration of conformance PS023  
      Accessories
      ACS-14Hopkinson bar calibration f for shock sensor-1 
       
      ACS-22frequency response,.traceable to NIST (100 Hz to ±1dB point)-1 
      (M) metric mounting
      mounting threadM6 x 0.75 male  
      (W)-waterproof Cable
      electrical connectionintegrated cord with waterproof connection  
      PCB-(M)350C04

      Specific References

      Download

      350C04_drawing.PDF

      Technical drawing

      Download (92.6k)

      350C04_manual.PDF

      Operating instructions

      Download (1.73M)

      350C04_specs.PDF

      Technical data sheet

      Download (83.13k)