PCB-352A25
    zoom_out_map

      PCB-352A25

      • ICP®-miniature vibration sensor,
      • Mass 0.6 grams.
      • Measuring range 2,000 g
      • Sensitivity 2.5 mV / g,.
      • Frequency range 1... 10,000 Hz,
      • 3-56 female connector on the side.
      • Including connection cable, length 3 m,
        ending on 10-32 plug

      basic data
      Sensitivity (± 15%)2.5 mV / g0.25 mV / (m / s)
      measuring range± 2,000 g pk± 19,600 m / s² pk
      Frequency range (± 5%)1.0 ... 10,000 Hz
      Frequency range (± 10%)0.7 ... 13,000 Hz
      Frequency range (± 3 dB)0.3 ... 20,000 Hz
      resonant frequency≥80.000 Hz
      Broadband resolution0.01 g RMS0.1 m / s RMS[1]
      linearity error≤1%[2]
      Lateral acceleration sensitivity≤5%
      Operating conditions
      Overload limit (shock)± 10,000 g pk± 98,000 m / s² pk
      The temperature range (operation)-65 ... 250 ° F-54 ... 121 ° C[3]
      Technical characteristics
      supply voltage18 ... 30 V DC
      Constant current supply2 ... 20 mA
      output impedance?300 ?
      Bias voltage7 ... 11 V DC
      discharging1.0 ... 3.5 s
      Settling time 
      (on the bias voltage ± 10%)
      <3 s
      Spectral Noise (1 Hz)4500 µg/√Hz44,100 (µm/s²)/√Hz[1]
      Spectral noise (10 Hz)1250 µg/√Hz12,250 (µm/s²)/√Hz[1]
      Spectral noise (100 Hz)300 µg/√Hz2,940 (µm/s²)/√Hz[1]
      Spectral noise (1,000 Hz)100 µg/√Hz980 (µm/s²)/√Hz[1]
      physical properties
      Size - Height0.14 in3.6 mm
      Size - Length0.45 in11.4 mm
      Size - Width0.25 in6.4 mm
      Dimensions0.02 oz0.6 grams[1]
      sensor elementceramics
      Geometry of the sensor elementshear principle
      housing materialtitanium
      sealepoxy resin
      electrical connection3-56 Coaxial
      port locationLaterally
      attachmentadhesive mounting
      Hints
      [1]typically,
      [2]Zero-based line of best fit, determined by the method of least squares
      [3]The data for temperatures above 121 ° C only apply to transducers with HT option.
      [4]Details: see PCB Declaration of Conformance PS023
      included supply
      030A10Coaxial cables, 3 meters, 3-56 plug to plug 10-32-1
      039A27Lifting tool for models 352A21, 352C22, 352A25, 357A09, 357C10-1
      080A109mounting wax-1
      ACS-1Frequency response, traceable to NIST (10 Hz up to the top 5% point)-1
      (HT) High temperature electronics
      temperature range-65 ... 325 ° F-54 ... 163 ° C
      PCB-352A25

      Specific References

      Download

      352A25_drawing.PDF

      Technical drawing

      Download (98.93k)

      352A25_specs.PDF

      Technical data sheet

      Download (31.69k)

      352A25_manual.PDF

      Operating instructions

      Download (1.69M)