PCB-356M98
    zoom_out_map

      PCB-356M98

    • Triaxialer ICP® vibration sensor for vacuum applications,
    • Low outgassing
    • Measuring range 5 g,
    • Sensitivity 1,000 mV / g,
    • Frequency range 0.5 … 3,000 Hz,
    • 4-pin female connector on the side
    • basic data
      sensitivity (±10%)1,000 mV / g102 mV/(m/s²)
      range± 5 g pk ±49 m/s² pk
      frequency range (±5%)0.5 … 3,000 Hz
      Frequency range (± 10%)0.3 … 5,000 Hz
      resonance frequency≥ 20,000 Hz
      phase response (at 21 ° C) (± 5 °)2 … 2,000 Hz
      wide band resolution0.00005 g RMS0.0005 m/s² RMS[1]
      Linearity≤ 1%[2]
      transverse acceleration sensitivity≤ 5%
      conditions of use
      Overload limit (shock)±5. 000 g pk
      Temperature range (operation)20 … 170 ° F29 … 77 ° C
      strain sensitivity (footprint)0.0007 g/µε0.007 (m/s²)/µε[1]
      technical characteristics
      Supply20 … 30 V DC
      constant power supply2 … 20 mA
      Output impedance≤ 600 Ω
      Bias voltage8 … 12 V DC
      Discharging charging time constant0.8 … 3.0 s
      settling time < br(auf Bias-Spannung ±10 %)>12s
      Spectral noise (1 Hz)11.4 µg / √ Hz112 (µm / s ²) / √ Hz[1]
      spectral noise (10 Hz)4.0 µg / √ Hz39 (µm / s ²) / √ Hz[1]
      Spectral noise (100 Hz)1.2 µg / √ Hz12 (µm / s ²) / √ Hz[1]
      spectral noise (1,000 Hz)0.4 µg / √ Hz4.4 (& tone micronso; m/s²) / √ Hz[1]
      physical properties
      sensor elementceramic
      geometry of the sensor elementshear principle
      Housing materialtitanium
      sealinghermetically sealed
      size - H öhe0,80 in20.3 mm
      size - length1.03 in26.1 mm
      size - width0.80 in20.3 mm
      Mass1.34 oz39 grams[1]
      wiring1/4 "-28 4-pin
      " Connecting positionside
      mounting thread10-32 female thread
      notes
      [1]typically
      [2]zero-based balancing line, determined using the method of least squares
      [3]details: see PCBs Declaration of conformance PS023
      IncludedAccessories
      080A109mounting wax-1
      080A68adhesive mounting, 22.2 mm hex, 10-32 thread, anodized aluminum-1
      081 B 05mounting bolts (10-32 on 10-32)-1
      ACS-1 T Frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency-1
      (T) TEDS memory in accordance with IEEE PP1451. 4
      Bias voltage 8.5 … 13 V DC
      (TLA) TEDS LMS International - free format
      Bias voltage8.5 … 13 V DC
      (TLB) TEDS LMS international - format for the automotive industry
      Bias voltage8.5 … 13 V DC
      (TLC) TEDS LMS international - format for the aviation industry
      Bias voltage8.5 … 13 V DC
      (TLD)TEDS memory in accordance with IEEE P1451. 4
      Bias voltage8.5 … 13 V DC
      PCB-356M98

      Specific References

      Download

      356M98_drawing.PDF

      Technical drawing

      Download (688.04k)

      356M98_manual.PDF

      Operating instructions

      Download (2.3M)

      356M98_specs.PDF

      Technical data sheet

      Download (80.4k)