PCB-339A30/NC
basic data | |||
sensitivity (±10%) | 10 mV / g | 1.02 mV/(m/s²) | |
range | ±500 g pk | ±4. 905 m/s 2 pk | |
frequency range (±5%) | 2 … 8,000 Hz | ||
Resonance frequency (X - and Y-axes) | ≥ 25,000 Hz | ||
Resonance frequency (Z axis) | ≥ 55,000 Hz | ||
type of filter | first-order low-pass | ||
slope the filter | 6 dB/octave | ||
electric filter corner frequency | > 14,000 Hz | ||
wide band resolution | 0.008 g RMS | 0.078 m/s² RMS | [1] |
Linearity | ≤ 0.5% | ||
transverse acceleration sensitivity | ≤ 5% | ||
conditions of use | |||
Overload limit (shock) | ±5. 000 g pk | ±49. 050 m/s² pk | |
Temperature range (operation) | -65 … 325 ° F | -54 … 163 ° C | |
Temperature coefficient of sensitivity | ≤0,011 %/°F | ≤ 0.020 %/°C | |
Specifications | |||
power supply | 18 … 30 V DC | ||
Constant power supply | 2 … 20 mA | ||
output impedance | ≤200Ω | ||
Bias voltage (at room temperature) | 7 … 11 V DC | ||
discharging charging time constant | 0.6 … 2 s | ||
settling time (on Bias-Spannung ±10%) | < 3 s | ||
spectral noise (1 Hz) | 1,700 µg / √ Hz | 16,660 (µm / s ²) / √ Hz | [1] |
Spectral noise (10 Hz) | 500 µg / √ Hz | 4,900 (µm / s ²) / √ Hz | [1] |
Spectral noise (100 Hz) | 200 µg / √ Hz | 1.960 (µm / s ²) / √ Hz | [1] |
spectral noise (1,000 Hz) | 100 µg / √ Hz | 980 (µm / s ²) / √ Hz | [1] |
physical properties | |||
geometry of the sensor element | shear principle | ||
housing material | titanium | ||
Sealing | hermetically sealed | ||
size - height | 0.4 in | 10.2 mm | |
Size - length | 0.4 in | 10.2 mm | |
Size - width | 0.4 in | 10.2 mm | |
weight | 0.14 oz | 4 grams | [1] |
electric Connection | 8-36 4-Pin | ||
connection position | side | ||
attachment | bonding | ||
Notes | |||
[1] | typically | ||
[2] | details: see PCBs Declaration of conformance PS023 |