PCB-(M)224C

PCB-(M)224C

  • ICP® force measuring element,
  • Range 35.6 … 129 kN,
  • Sensitivity 45 mV / kN,
  • Frequency range 0.0003 … 8,000 Hz,
  • 10-32 female connector on the side
  • basic data
    sensitivity (±15%)0.20 mV / lb44,96 mV / kN
    measuring range (pressure)25,000 lb111.2 kN
    Measuring range (traction)8,000 lb35,59 kN
    maximum permissible static load (force)29,000 lb129.00 kN
    Maximum permissible static load (traction)10,000 lb44.48 kN
    wide band resolution0.60 lb RMS2.67 N RMS[1]
    Lower limiting frequency (-5%)0.0003 Hz[2]
    upper frequency limit8,000 Hz[4]
    linearity error≤ 1.5% FS[3]
    conditions
    temperature range-65 … 250 ° F-54 … 121 ° C
    Temperature coefficient of sensitivity≤ 0.03 %/°F≤ 0,054 %/°C
    technical properties
    discharge charge time constant (at room temperature)≥ 2,000 sclose
    electrical connection10-32-coaxial socket
    connection positionside
    Mounting thread5/8-18 female
    notes
    [1]typically
    [2]on the basis of the Calculated discharge charge time constant
    [3]zero-based balancing line, determined using the method of least squares
    [4] Accepted value determined on the basis of solid state Dynamics calculations
    (M) metric mounting
    (S) negative output polarity
    (W) waterproof cable connection
    electrical connectionsealed cable connection
    cable outletSide

    29 other articles of the same category: