PCB-(M)223B

PCB-(M)223B

  • ICP® force measuring element,
  • Range 17.8 … 53 kN,
  • Sensitivity 94 mV / kN,
  • Frequency range 0.0003 … 10,000 Hz,
  • 10-32 female connector on the side
  • of
    basic data
    sensitivity (±15%)mV 0.42 / lb94,42 mV / kN
    measuring range (pressure)12,000 lb53,38 kN
    Measuring range (traction)4,000 lb17.79 kN
    maximum permissible static load (force)10,000 lb44.48 kN
    maximum static force (traction)4,500 lb20,02 kN
    wide band resolution0.40 lb RMS1.78 N RMS[1]
    Lower limiting frequency (-5%)0.0003 Hz[2]
    upper cut-off frequency10,000 Hz[4]
    linearity error≤ 1% FS[3]
    conditions
    temperature range-65 … 250 ° F-54 … 121 ° C
    temperature coefficient Temperature coefficient of sensitivity≤ 0.03 %/°F≤ 0,054 %/°C
    technical properties
    discharge charge time constant (at room temperature)≥ 2,000 s
    Notes
    [1]typically
    [2]calculated using the discharge load time constant
    [3]zero-based balancing line, determined using the method of least squares
    [4]suppose value determined on the basis of solid state Dynamics calculations
    [5]details: see PCBs Declaration of conformance PS023
    (M) metric mounting
    (S) negative output polarity
    (W) waterproof cable connection
    electrical connectionsealed cable connection
    cable exitside

    29 other articles of the same category: