PCB-(M)222B

PCB-(M)222B

  • ICP® force measuring element,
  • Range 11,1 … 26.7 kN,
  • Sensitivity 202 mV / kN,
  • Frequency range 0.0003 … 12.000 Hz,
  • 10-32 female connector on the side
  • basic data
    sensitivity (±15%)0.90 mV / lb202,33 mV / kN
    measuring range (pressure)6,000 lb26,69 kN
    Measuring range (traction)2,500 lb11,12 kN
    maximum permissible static load (force)6,000 lb26,69 kN
    maximum static force (traction)2,800 lb12.46 kN
    wide band resolution0.2 lb RMS0,8896 N RMS[1]
    Lower limiting frequency (-5%)0.0003 Hz[2]
    upper frequency limit12.000 Hz[4]
    linearity error≤ 1% FS[3]
    conditions
    temperature range-65 … 250 ° F-54 … 121 ° C
    temperature coefficient Temperature coefficient of sensitivity≤ 0.03 %/°F≤ 0,054 %/°C
    technical properties
    discharge charge time constant (at room temperature)≥ 2,000 s
    Supply20 … 30 V DC
    constant power supply2 … 20 mA
    Output impedance≤ 100 Ω
    Bias voltage8 … 14 V DC
    Physical properties
    rigidity3 lb/µin0.53 kN/µm[1]
    size - diameter0,870 in22.1 mm
    Size - height1,620 in41,51 mm
    weight2 oz58 grams
    parts usematerialstainless steel
    sealinghermetically sealed
    electrical connection10-32-coaxial socket
    Connection positionside
    mounting screw3/8-24 female
    notes
    [1]Typically
    [2]calculated on the basis of discharging charging time constant
    [3]zero-based balancing line, determined using the method of least squares
    [4]suppose value determined on the basis of solid state Dynamics calculations
    (M) metric mounting
    (S) Negative output polarity
    (W) waterproof cable connection
    electrical connectionsealed cable connection
    Cable exitside

    29 other articles of the same category: