PCB-3711E11200G
    zoom_out_map

      PCB-3711E11200G

    • MEMS-DC acceleration sensor,
    • Suitable for measuring static accelerations,
    • Measuring range 200 g
    • Sensitivity 10 mV / g,
    • Typical frequency range 0 … 3,000 Hz,
    • Supply voltage 6 … 30 V DC,
    • 4-pin female connector on the side
    • basic data
      sensitivity (±3%)10 mV / g1.02 mV/(m/s²) 
       
      measuring range±200 gpk±1. 962 m/s² pk 
       
      Frequency range (± 3 dB)0 … 3,000 Hz [2]
       
      frequency range (± 3 dB)0 … 1500 Hz [3]
       
      Phase response< 10 °  
       
      wide band resolution (0,5 … 100 Hz)[2]0.04 m/s² rmsrms 4 mg
       
      Linearity error≤1% [1]
       
      transverse acceleration sensitivity≤5%  
      conditions
      Overload limit (Shock)±5. 000 g pk±49. 050 m / pk 
       
      Temperature range (operation)-65 … 250 ° F-54 … 121 ° C 
       
      temperature range (storage)-65 … 250 ° F-54 … 121 ° C 
       
      Temperature coefficient of sensitivity±3% [4]
       
      temperature coefficientzero±2% FSO [4] [5]
       
      strain sensitivity (footprint)0.001 g/µε0.01 (m/s²)/µε[2]
       
      Magnetic sensitivity100µg/Gs/9.8 (m/s²) / T[2]
      technical specifications
      power supply6 … 30 V DC  
       
      Power? 12 mA  
       
      output impedance? 120 ?  
       
      Spannungsoffset±80 mV DC [6]
       
      spectral noise (1 … 100 Hz)500 µg / √Hz4.905 (µm / s ²) / √Hz[2]
       
      electrical insulation (base)>100 MΩ  
      physical properties
      housing materialtitanium  
       
      Sealinghermetically sealed  
       
      size - height0.45 in11.4 mm 
       
      Gr öße - L &AmericanCatholic.org; length0.85 in21.6 mm 
       
      size - width0.85 in21.6 mm 
       
      mass0.58 oz16.3 grams 
       
      Electrical connection4-Pin  
       
      connectionon the side  
       
      mountingtwo through holes  
      Notes
      [1]zero-based balancing line, determined using the method of least squares  
       
      [2]typically  
       
      [3]guaranteed; evidenced by calibration certificate supplied with  
       
      [4]-54 … 121 ° C, reference 24 ° C  
       
      [5]FSO = "Full Scale Output": maximum output signal of the measuring range (4 V DC).  
       
      [6]offset at 3 meters cable length (type 010)  
       
      [7]details: see PCB Declaration of Conformance PS027  
      Accessories supplied
      080A152mounting clip-1 
       
      081A113mounting screw with 4-40 thread2 
       
      M081A113mounting screw m2, 5 thread2 
       
      ACS-145Calibration of amplitude and phase of 2 Hz up to the upper ±3dB point-1 
      PCB-3711E11200G

      Specific References

      Download

      3711E11200G_drawing.PDF

      Technical drawing

      Download (200.7k)

      3711E11200G_manual.PDF

      Operating instructions

      Download (393.48k)

      3711E11200G_specs.PDF

      Technical data sheet

      Download (80.41k)