PCB-3711B1210G
    zoom_out_map

      PCB-3711B1210G

    • MEMS accelerometer,
    • Suitable for measuring static accelerations,
    • Measuring range 10 g,
    • Sensitivity200 mV / g,
    • Frequency range 0 … 1,000 Hz,
    • Supply voltage 6 … 30 V DC,
    • Integrated cable, length 3 m,
      ending on stripped and tinned ends
    • basic data
      sensitivity (±5%)200 mV / g20.4 mV/(m/s²)
      range±10 g pk ±98, 1 m/s 2 pk
      frequency range (±5%)0 … 1,000 Hz
      Frequency range (± 10%)0 … 1500 Hz
      resonance frequency≥ 2.000 Hz
      phase response (100 Hz)< 10 °
      wide band resolution1.2 mg rms0,012 m/s² RMS[3]
      Linearitä avoidable≤ 1%[2]
      transverse acceleration sensitivity≤ 3%
      conditions of use
      Overload limit (shock)±3. 000 g pk±29. 420 m/s² pk
      Temperature range (operation)-65 … 250 ° F-54 …121 ° C
      temperature range (storage)-65 … 250 ° F-54 … 121 ° C
      Temperature coefficient of sensitivity≤3%[1]
      Temperature coefficient of sensitivity the zero point±2% FSO[1] [4]
      strain sensitivity (base area)0.0001 g/µε0.001 (m/s²)/µε[3]
      magnetic sensitivity10.5µg/GS/1.03 (m/s²) / T[3]
      technical characteristics
      Supply6 … 30 V DC
      power&le≤6 mA
      Output impedance≤ 100 Ω
      Spannungsoffset± 40 mV DC[5]
      spectral noise (1)107.9 µg /. √ Hz1,058 (µm / s ²) / √ Hz[3]
      electrical insulation (housing)≥ 100 MΩ
      physical properties
      Housing materialTitanium
      Sealedsealedclose
      size - height0.45 in11.4 mm
      size - length0.85 in21.6 mm
      Size - width0.85 in21.6 mm
      dimensions (with cable)2.29 oz65.0 grams
      electrical connectionIntegrated cable
      Cable exitside
      cable terminationtinned ends
      cable type Type 010, 4-wire shielded cable
      cable length10 ft3 m
      mountinghole
      Notes
      [1]-54 … 121 ° C, reference 24 ° C
      [2]zero-based balancing line, determined using the method of least squares
      [3]typically
      [4] FSO = "Full Scale Output": maximum output signal of the measuring range (4 V )(DC).
      [5]offset at 3 meters cable length (type 010)
      [6]details: see PCB Declaration of Conformance PS027
      Equipment
      080A152mounting clip-1
      081A113mounting screw-2
      ACS-85calibration of amplitude and phase-1
      M081A113metric mounting screw-2
      PCB-3711B1210G

      Specific References

      Download

      3711B1210G_drawing.PDF

      Technical drawing

      Download (192.04k)

      3711B1210G_manual.PDF

      Operating instructions

      Download (785.4k)

      3711B1210G_specs.PDF

      Technical data sheet

      Download (426.68k)