SYN-CW-219B/NC

Vibration monitor SYN-CW-219 B / NC

  • Machine status monitor,
  • Inputs: ICP®, 4... 20 mA, 0... 10 V,
  • 2 adjustable alarm thresholds,
  • Alarm release according to appropriate sizes,
  • Pre-alarm and main alarm relay,
  • Hardware monitoring,
  • Crest, narrow band level analysis,
    se. RMS frequency band setting

Input
Vibration measurementICP® power supply, 4 mA at 20... 30 V
Sensitivity 10... 1000 mV / g
Resolution 4 mg (at Sensitivit? 100 mV/g)
Digital review filter
-RMS level: 10... 1,000 Hz in accordance with DIN ISO 10816-1
  bzw. 2 … 1.000 Hz, 2.000 Hz, 3.000 Hz, 5.000 Hz (einstellbar)
-Transient shock: HP 1,000 Hz, 2,000 Hz, 4,000 Hz, 6,000 Hz
  (einstellbar) bis?50.000 Hz für Transientenerfassung
  
 
Temperature measurementVoltage input 0... 2 V, sensitivity adjustable
Suitable for the connection of vibration sensors with
Option "TO"
  
 
Process parameters0... 20 mA, Signalber. scalable up to 120%  
 
SpeedCW-219-0... 20 mA, Signalber. scalable (300... 12,000 rpm)
CW-220: active or passive rotary encoders
-Number of pulses: 1... 720 pulse per revolution (adjustable)
-Max frequency: 36,000 Hz
-Reference pulse 1 x per revolution for position determination
  
Outputs
Switching relay1 x closer, 1 x opener with security control
Alarms can be configured
Maximum switching voltage 48 V, maximum switching current 1 A
  
 
Time signal vibrationNon-valuated analog sensor signal  
Interfaces
Configuration and online modeCAN-bus with USB adapter
LAN and Wi-Fi in conjunction with module CW-103
  
General information
Supply voltage24 V DC nominally, working range 20... 30 V DC  
 
Power consumptionApprox. 80 mA (at 24 V)  
 
Galvanic isolationCurrent interface and CAN-bus  
 
Temperature range-10... 70 ° C  
 
Type of protectionIP20  
 
HousingDIN rail housing with screw-type  
 
Dimensions (WxHxD)45 x 120 x 120 mm  
Additional informations
Input 1 x ICP®
  • 2 x 4... 20 mA
  • 1 x 0... 10 V
 
 
Signal evaluation RMS acceleration
  • RMS speed
  • Shock level
  • Crest factor
  • Narrow band level analysis
  • ERW. RMS frequency band setting
 
 
Monitoring functions 2 adjustable alarm thresholds
  • Alarm release depending on appropriate size
  • Pre-alarm relay
  • Main alarm relay
  • Hardware monitoring
 