PCB-356M208

PCB-356M208

  • Triaxial ICP® miniature vibration sensor for vacuum applications,
  • Low outgassing

,

  • measuring range 1000 g,
  • sensitivity 5 mV / g,
  • frequency range 2 … 8,000 Hz,
  • mass 1 gram,
  • integrated cable, length 1.5 m, ending on 4 PIN Jack,
  • including extension cable, length 6 meter, ending to three BNC

basic data
Sensitivity (± 20%)5 mV / g0.51 mV / (m / s)
measuring range± 1.000 g pk± 9,810 m / s² pk
Frequency range (Y- and Z-axis) 
(± 5%)
2 ... 8000 Hz
Frequency range (X-axis) (± 5%)2 ... 5000 Hz
Frequency range (X-axis) (+1 dB)≥8.000 Hz
resonant frequency≥50.000 Hz
Broadband resolution0.003 g RMS0.03 m / s RMS[3]
linearity error≤1%[2]
Lateral acceleration sensitivity≤5%
Operating conditions
Overload limit (shock)± 10,000 g pk± 98,100 m / s² pk
The temperature range (operation)-65 ... 250 ° F-54 ... 121 ° C
Technical characteristics
supply voltage18 ... 30 V DC
Constant current supply2 ... 20 mA
output impedance≤200 Ω
Bias voltage7 ... 11 V DC
discharging0.24 ... 1.0 s
Settling time 
(on the bias voltage ± 10%)
<3 s
Spectral Noise (1 Hz)1200 µg/√Hz11,772 (µm/s²)/√Hz[3]
Spectral noise (10 Hz)300 µg/√Hz2,943 (µm/s²)/√Hz[3]
Spectral noise (100 Hz)100 µg/√Hz981 (µm/s²)/√Hz[3]
Spectral noise (1,000 Hz)30 µg/√Hz294 (µm/s²)/√Hz[3]
physical properties
sensor elementceramics
Geometry of the sensor elementshear principle
housing materialtitanium
sealhermetically sealed
Size - Height0.25 in6.35mm
Size - Length0.25 in6.35mm
Size - Width0.25 in6.35mm
Weight (without cable)0.04 oz1.0 grams[3]
electrical connectionintegrated cable[1]
cable outletLaterally
cable length5 ft1.5 m
cable typeType 034, shielded 4-wire cable
attachmentadhesive mounting
Hints
[1]TML: ?1% CVCM: ?0,1%
[2]Zero-based line of best fit, determined by the method of least squares
[3]typically,
[4]Details: see PCB Declaration of Conformance PS023
included supply
034M22Cables with low outgassing rate, 4-pin plug on three BNC connector-1
080A109mounting wax-1
080A90superglue-1
ACS-1TFrequency response for triaxial receiver, traceable to NIST, 10 Hz up to the top 5% -frequency-1