PCB-(M)627A71
basic data | ||||
sensitivity (±15%) | 100 mV/g | 10.2 mV/(m/s²) | [5] | |
measuring range | ±50 g | ±490 m / s² | ||
Frequency range (± 3 dB) | 20 … 600,000 cpm | 0.33 … 10,000 Hz | [4] | |
resonance frequency | 1,080 kcpm | 18,000 Hz | [3] | |
Wide band resolution | 1,000 µg | 9,810 µm / s ² | [3] | |
linearity | ≤1% | [1] | ||
Transverse acceleration sensitivity | ≤ 5% | |||
conditions of use | ||||
Overload limit (shock) | 5,000 g pk | 49,050 m/s² pk | ||
temperature range | -65 …200 °F | -54 … 93 ° C | ||
Type of protection | IP64 | |||
Technical characteristics | ||||
settling time (on bias voltage ± 1%) | ≤ 10s | |||
discharging charging time constant | ≥ 0<5 s | Equivalent | [2] | |
Assembly torque | 2 … 5 ft-lb | 2.7 … 6.8 Nm | ||
sensor element | quartz | |||
Geometry of the sensor element | shear principle | |||
housing material | stainless steel | |||
sealing | hermetically sealed welded | |||
electrical connection | terminals | |||
connection position | above | |||
Notes | ||||
[1] | zero-based balancing line, determined using the method of least squares | |||
[2] | no equivalent in SI units | |||
[3] | typically | |||
[4] | the upper cut-off frequency tolerance: ±10% | |||
[5] | Conversion factor 1 g = 9.81 m/s² | |||
[6] | details: see PCBs Declaration of conformance PS023 | |||
equipment | ||||
081A40 | mounting bolts with 1 / 4 & quot;-28 thread | -1 | ||
(M) metric mounting | ||||
equipment | ||||
M081A61 | metric mounting bolts with M6 threads | -1 |