PCB-(M)607A61

PCB-(M)607A61

  • Industrial ICP® vibration sensor,
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 0.5 … 10,000 Hz,
  • One-point calibration at 100 Hz,
  • Free ausrichtbares integrated connecting cable with reinforcement, length 3 m,
    ending on cut end
  •  

    basic data
    sensitivity (±15%)100 mV/g10.2 mV/(m/s²)[6]
     
    measuring range±50 g±490 m / s² 
     
    Frequency range (± 3 dB)30 … 600,000 cpm0.5 … 10,000 Hz 
     
    resonance frequency1,500 kcpm25,000 Hz[1]
     
    Wide band resolution350 µg3.434 µm / s ²[1]
     
    linearity≤1% [3]
     
    Lateral acceleration sensitivity≤ 7%  
    Conditions of use
    Overload limit (shock)5,000 g pk49,050 m/s² pk 
     
    Temperature range-65 … 250 ° F-54 … 121 ° C 
     
    protection classIP67  
    technical characteristics
    Settling time (on bias voltage ± 1%)≤ 2 s  
     
    discharging charging time constant≥0.3 s    
     
    [5]two-core cable with stainless steel reinforcement  
     
    [6]conversion factor 1 g = 9.81 m/s²  
     
    [7]Assembly requires Allen key 1/8 "(for inch mounting bolts) or 3 mm (for metric mounting bolts).  
     
    [8]of the mounting bolts must be tightened with a higher torque than the hex nut, so that the sensor can easily be removed.  
     
    [9]details: see PCBs Declaration of conformance PS023 and PS060  
    Accessories
    080A156mounting bolts 1/2 "-20 1/4" 28-1 
     
    ICS-2single point calibration at 100 Hz (traceable to NIST)-1 
    (M) metric mounting
    equipment   
     
    M080A159Amounting bolts 1/2 "20 M6 x 1-1 
    (TO) temperature output
    temperature range36 & Emmap; 250 ° F2 … 121 ° C 
     
    transcription factor5.56 mV / ° F
    (zero point at 32 °F)
    10 mV / ° C 
     
    electrical connectionIntegrated armoured cable  
     
    connections (red wire)acceleration output  
     
    (black wire) pin assigNmentMass  
     
    Pin assigNment (white wire)temperature output  
    (EX) with ATEX approval
    approved for explosive atmosphere erasCL I, div 2, groups A, B, C, D ExnL IIC T4, AExnA IIC T4  
     
    approval for use in potentially explosive atmospheresEEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 3 G  
     
    Approval for use in potentially explosive atmospheresEEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 1 G  
     
    approval for explosionsgef ährdete atmospheresCL I, div I, groups A, B, C, D CL II, div I, groups E, F, G Cl III, div I  
     
    approval for use in potentially explosive atmospheresExIA IIC T4, AExia IIC, T4  

    29 other articles of the same category: