PCB-(M)602D11

PCB-(M)602D11

  • Industrial ICP® vibration sensor,
  • With through hole,
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 0.5 … 8,000 Hz,
  • One-point calibration at 100 Hz,
  • Integrated cable, length 3 m,
    ending on cut end
  •  

    basic data
    sensitivity (±10%)10.2 mV/(m/s²)[6]
     
    measuring range±50 g±490 m / s² 
     
    Frequency range (± 3 dB)30 … 480,000 cpm0.5 … 8,000 Hz[2]
     
    resonance frequency1,500 kcpm25,000 Hz[1]
     
    Wide band resolution350 µg3.434 µm / s ²[1]
     
    linearity≤1% [3]
     
    Transverse acceleration sensitivity≤ 7%  
    conditions of use
    Overload limit (shock)5,000 g pk49,050 m/s² pk 
     
    temperature range-65 … 250 ° F-54 … 121 ° C 
     
    Type of protectionIP68  
    Technical characteristics
    settling time (on bias voltage ± 1%)≤2.0 s  
     
    discharging charging time constant≥0.3 s  
     
    Power18 … 28 V DC  
     
    constant power supply2 … 20 mA  
     
    Output impedance< 150 Ω  
     
    Bias voltage8 … 12 V DC  
     
    Spectral noise (10 Hz)8.0 µg / √Hz78.5 (µm / s ²) / √Hz[1]
     
    spectral noise (100 Hz)5 µg / √Hz49.1 (µm / s ²) / √Hz[1]
     
    Spectral noise (1,000 Hz)4 µg / √Hz39.2 (µm / s ²) / √Hz[1]
     
    electrical insulation (housing)  
    Physical properties
    size - length3.70 in94 mm 
     
    size - width0.74 at18.8 mm 
     
    Size - height0,845 in21.5 mm 
     
    dimensions (without cable)2.61 oz74.0 grams 
     
    Mounting thread1/4"-28No metric equivalent[4]
     
    Assembly torque2 … 5 ft-lb2.7 … 6.8 Nm 
     
    Sensor elementceramic  
     
    geometry of the sensor elementshear principle  
     
    housing materialstainless steel  
     
    Sealinghermetically sealed welded  
     
    electrical connectionpotted integrated cable  
     
    Cable exitside  
     
    cable length10 ft3.0 m 
     
    cable typepolyurethane [5]
    Notes
    [1]typically  
     
    [2]the upper cut-off frequency tolerance: ±10%  
     
    [3]zero-based balancing line, determined using the method of least squares  
     
    [4]mounting with M6 screw possible  
     
    [5]two-wire shielded cablewith twisted wire  
     
    [6]conversion factor 1 g = 9.81 m/s²  
     
    [7]details: see PCBs Declaration of conformance PS023 and < a href = ""... "/ produkte_skript/downloads/ce/ps060.pdf" "class ="blue"> PS060  
    equipment
    081A97passage screw 1/4" 28-1 
     
    ICS-2single point calibration at 100 Hz (traceable to NIST)-1 
    (M) metric mounting
    equipment   
     
    M081A97metric mounting bolt with M6 thread-1 
    (TO) temperature output
    temperature range36 … 250 ° F2 … 121 ° C 
     
    Transcription factor5.56 mV / ° F
    (zero point at 32 °F)
    10 mV / ° C 
     
    electrical connectionpotted integrated cable  
     
    Pin assigNment (green wire)ground  
     
    (black wire) pin assigNmentmass  
     
    (white wire)Temperature output  
     
    Connections (red wire)acceleration output  
    (EX) with ATEX approval
    approved for explosive atmosphere erasExIA IIC T4, AExia IIC, T4  
     
    approval for use in potentially explosive atmospheresEEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 3 G  
     
    Approval for use in potentially explosive atmospheresEEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 1 G  
     
    approved for explosive atmosphere renCL I, div I, groups A, B, C, D CL II, div I, groups E, F, G Cl III, div I  
     
    approval for use in potentially explosive atmospheresCL I, div 2, groups A, B, C, D ExnL IIC T4, AExnA IIC T4  

    29 other articles of the same category: