PCB-(M)601A92

PCB-(M)601A92

  • Industrial ICP® vibration sensor,
  • Measuring range 10 g,
  • Sensitivity500 mV / g,
  • Frequency range 0.17 … 10,000 Hz,
  • One-point calibration at 100 Hz,
  • M12 connection socket top
  •  

    basic data
    sensitivity (±20%)500 mV / g51 mV/(m/s²)[1]
     
    measuring range± 10 g±98 m / s² 
     
    Frequency range (±5%)28 … 240,000 cpm0.47 … 4,000 Hz[4]
     
    frequency range (± 10%)20 … 300,000 cpm0.33 … 5,000 Hz 
     
    frequency range (± 3 dB)10 … 600,000 cpm0.17 … 10,000 Hz 
     
    resonance frequency960 kcpm16,000 Hz[2]
     
    wide band resolution (1 … 10,000 Hz)35 µg343 µm / s ²[2]
     
    linearity≤1% [3]
     
    Transverse acceleration sensitivity≤ 7%  
    conditions of use
    (shock) overload limit49,050 m/s ² pkpk 5,000 g 
     
    Temperature range-65 … 250 ° F-54 … 121 ° C 
     
    temperature impact on Temperature coefficient of sensitivitysee curve below [2]
     
    Protection classIP68  
    technical characteristics
    settling time (on area within ±1% of the bias voltage)? 10s  
     
    Discharging charging time constant≥ 1.0 s  
     
    power18 … 28 V DC  
     
    Constant power supply2 … 20 mA  
     
    output impedance< 150 Ω  
     
    bias voltage8 … 12 V DC  
     
    spectral noise (10 Hz)3 µg / √Hz29.4 (µm / s ²) / √Hz[2]
     
    Spectral noise (100 Hz)0.7 µg / √Hz6.9 (µm / s ²) / √Hz[2]
     
    spectral noise (1,000 Hz)0,5 µg / √Hz4.9 (µm / s ²) / √Hz[2]
     
    electrical insulation  
    physical properties
    size - hex7/8 in22.2 mm 
     
    Size - height1.82 in46.3 mm 
     
    weight2.8 oz80 g 
     
    mounting thread1/4 "internal threadNo metric equivalent[5]
     
    Assembly torque2 … 5 ft-lb2.7 … 6.8 Nm 
     
    sensor elementceramic  
     
    geometry of the Sensor elementshear principle  
     
    housing materialstainless steel (316 L)  
     
    sealinghermetically sealed welded  
     
    Connectiontop  
    notes
    [1]conversion factor 1 g = 9.81 m/s²  
     
    [2]Typically  
     
    [3]zero-based balancing line, determined using the method of least squares  
     
    [4]the upper cut-off frequency tolerance: ±10%  
     
    [5]no equivalent in SI units  
     
    [6]Details: see PCBs Declaration of conformance PS023  
    Equipment
    081A40mounting bolts with 1/4 "-28 thread-1 
     
    ICS-2single point calibration at 100 Hz (Rü" ckführbar on NIST)-1 
    (M) metric mounting
    equipment   
     
    M081A61metric mounting bolts with M6-thread-1 

    29 other articles of the same category: