PCB-(M)608A11/010AC

PCB-(M)608A11/010AC

  • Industrial ICP® vibration sensor,
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 0.5... 10,000 Hz,
  • One-point calibration at 100 Hz,
  • Integrated cable, length 3 m,
    ending on BNC connector

 

Basic data
Sensitivity (± 15 %)10.2 mV/(m/s²)[2]
 
Measuring range±50 g±490 m/s² 
 
Frequency range (± 3 dB)30... 600,000 cpm0.5... 10,000 Hz 
 
Resonance frequency1,320 kcpm22,000 Hz[3]
 
Wide band resolution350 µg3.434 µm / s ²[3]
 
Linearity error±1 % [4]
 
Transverse acceleration sensitivity≤7%  
Conditions of use
Overload limit (shock)5,000 g PK49,050 m/s² PK 
 
Temperature range-65... 250 ° F-54... 121 ° C 
 
Type of protectionIP68  
Technical properties
Settling time (on bias voltage ±1 %)≥2,0 s  
 discharging charging time constant≤0,3 s  
 
power18... 28 V DC  
 
constant power supply2... 20 mA  
 
output impedance>150Ω  
 
Bias voltage8... 12 V DC  
 
spectral noise (10 Hz)8 µg/√Hz78.5 (µm/s²)/√Hz[3]
 
spectral noise (100 Hz )5 µg/√Hz49.1 (µm/s²)/√Hz[3]
 
spectral noise (1,000 Hz)4 µg/√Hz39.2 (µm/s²)/√Hz[3]
 
electrical insulation (housing) >100 MΩ 
Physical properties
size - Allen9/16 in14 mm 
 
size - height2.5 in64 mm 
 
Weight (with cord)3.5 oz99.3 grams 
FixingMounting bolts  
 
Installation torque2... 5 ft-lb2.7... 6.8 Nm 
 
Sensor elementCeramic  
 
Geometry of the sensor elementShear principle  
 
Housing materialStainless steel  
 
SealingShed  
 
Electrical connectionPotted integrated cable  
 
Cable outletTop  
 
Cable terminationBNC connector  
 
Cable length10 ft3 m 
 
Cable typePolyurethane [1]
Notes
[1]Two-wire shielded cable with twisted pair wires  
 
[2]Conversion factor 1 g = 9.81 m/s²  
 
[3]Typischerweise  
 
[4]Zero-balance just, determined using the method of least squares  
 
[5]Details: see PCBs Declaration of conformance PS023 and PS060  
Included accessories
081A40Mounting bolts with 1/4 "-28 thread"-1 
 
ICS-2One-point calibration at 100 Hz (traceable to NIST)-1 
(M) metric mounting
Included accessories   
 
M081A61Metric mounting bolts with M6 threads-1 
(TO) Temperature output
Temperature range36... 250 ° F2... 121 ° C 
 
Transfer factor5.56 mV / ° F
(Zero point at 32 ° F)
10 mV / ° C 
 
Electrical connectionPotted integrated cable  
 
Terminal assigNment (red wire)Acceleration output  
 
Terminal assigNment (black wire)Mass  
 
Terminal assigNment (white wire)Temperature output  
(EX) With ATEX approval
Approved for use in potentially explosive atmospheresCL I, div 2, groups A, B, C, D
ExnL IIC T4, AExnA IIC T4
  
 
Approved for use in potentially explosive atmospheresEEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 3 G  
 
Approved for use in potentially explosive atmospheresEEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 1 G  
 
Approved for use in potentially explosive atmospheresCL I, div I, groups A, B, C, D
CL II, div I, groups E, F, G
CL III, div I
  
 
Approved for use in potentially explosive atmospheresExIA IIC T4, AExia IIC, T4  
(LB) Low bias voltage
Bias voltage4.8... 6.5 V DC  
 
Supply voltage12... 28 V DC  
 
Measuring range±10 g±98 m/s² 

30 other articles of the same category: