PCB-(M)607M83

PCB-(M)607M83

  • Industrial ICP® vibration sensor 
    in 3- wire technology
  • No ICP® sensor power required
  • Measuring range 45 g
  • Sensitivity 100 mV / g
  • Frequency range 1.5 ... 10.000 Hz
  • One-point calibration at 100 Hz
  • Freely orientable integrated connection cable, length 3 meters, 
    ending on cut end

specifications
basic dataEnglish unitsSI units 
Sensitivity (± 20%)100 mV/g10,2 mV/(m/s²)[1]
measuring range±45 g±441 m/s²[4]
Frequency range (± 3 dB)90 … 600.000 cpm1,5 … 10.000 Hz
resonant frequency1.500 kcpm25.000 Hz[2]
Broadband resolution (1 ... 10,000 Hz)2 mg19,6 mm/s²[2]
linearity error±1 %[3]
Lateral acceleration sensitivity≤7 %
Operating conditions
Overload limit (shock)5.000 g pk49.050 m/s²pk
temperature range-65 … 250 °F-54 … 121 °C
protectionIP68
Technical characteristics
Settling time (on bias voltage ± 1%)≤5,0 s
discharging≥0,1 s
supply voltage3 … 12 VDC
output impedance<100 Ω
current consumption0.5 mA
Bias voltage1,5 … 6 VDC
Spectral noise (10 Hz)18 µg/√Hz176,6 (µm/s²)/√Hz[2]
Spectral noise (100 Hz)4 µg/√Hz39,2 (µm/s²)/√Hz[2]
Spectral noise (1,000 Hz)2 µg/√Hz19,6 (µm/s²)/√Hz[2]
Electrical insulation (housing)>100 MΩ
Physical properties
Size - hexagon9/16 in14 mm
Size - height0,97 in24,6 mm
Mass (without cable)1,1 oz31 grams[5]
attachmentmounting bolts
mounting thread1/4 "-28 male threadno metric equivalent[6]
Mounting torque (mounting bolt)7 … 8 ft-lb9,5 … 10,8 Nm[7][8]
Assembly torque (hexagon union nut)2 … 5 ft-lb2,7 … 6,8 Nm
sensor elementceramics
Geometry of the sensor elementScherprinzip
housing materialstainless steel
sealHermetically sealed
Electrical connectionPotted integrated cable
port locationLaterally
cable terminationCut off end
Pin assignment (red wire)Supply positive (+)
Pin assignment (black wire)Mass
Pin assignment (white wire)acceleration output
cable length10 ft3,0 m
cable typePolyurethan

Hints
[1]Conversion factor 1 g = 9,81 m / s²
[2]typically,
[3]Zero-based balancing line, determined by the least squares method
[4]Full measuring range only with sufficiently high supply voltage
[5]With mounting bolts
[6]No equivalent in SI units
[7]Installation requires 1/8 "hex keys (for imperial mounting bolts) or 3 mm (for metric mounting bolts).
[8]The mounting bolt must be tightened with a higher torque than the hexagon union nut, so that the sensor can be dismantled easily.

included supply
080A156Mounting bolt 1/2 "-20 to 1/4" -28(1)
ICS-2One-point calibration at 100 Hz (traceable to NIST)(1)

Available options
(M) Metric montage
included supply
M080A159AMounting bolt 1/2 "-20 to M6 x 1(1)