PCB-(M)607A11/030BZ

PCB-(M)607A11/030BZ

  • Industrial ICP® vibration sensor,
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 0.5 … 10,000 Hz,
  • One-point calibration at 100 Hz,
  • Free ausrichtbares integrated cable, length 9 metres, ending
    on cut end
  • "
    basic data
    sensitivity (±15%)100 mV/g10.2 mV/(m/s²)[7]
    measuring range±50 g±490 m / s²
    Frequency range (± 3 dB)30 … 600,000 cpm0.5 … 10,000 Hz
    resonance frequency1,500 kcpm25,000 Hz[1]
    Wide band resolution350 µg3.434 µm / s ²[1]
    linearity≤1%[6]
    Lateral acceleration sensitivity≤ 7%
    Conditions of use
    Overload limit (shock)5,000 g pk49,050 m/s² pk
    Temperature range-65 … 250 ° F-54 … 121 ° C
    protection classIP68
    technical characteristics
    Settling time (on bias voltage ± 1%)≤ 2 s
    discharging charging time constant≥ 0.3 sMounting torque (mounting bolts)7 … 8 ft-lb9.5 … 10.8 Nm[2] [3]
    Assembly torque (hex nut)2 … 5 ft-lb2.7 … 6.8 Nm
    sensor elementceramic
    Geometry of the sensor elementshear principle
    housing materialstainless steel
    sealinghermetically sealed welded
    electrical connectionpotted integrated cable
    cable exitside
    Cable length30 ft9.14 m
    cable typepolyurethane[5]
    notes
    [1]typically
    [2]Assembly requires Allen key 1/8 "(for inch mounting bolts) or 3 mm (for metric mounting bolts).
    [3]of the mounting bolts must be tightened with a higher torque than the hex nut, so that the sensor problemlos can be demounted again.
    [4]with mounting bolt
    [5]Screened two-wire cable with twisted wire
    [6]zero-based balancing line, determined using the method of least squares
    [7]conversion factor 1 g = 9.81 m/s²
    [8]details: see PCBs Declaration of conformance PS023 and < a href = ""... "/ produkte_skript/downloads/ce/ps060.pdf" "class ="blue"> PS060
    equipment
    080A156mounting bolts 1/2"-20 1/4"28-1
    ICS-2single point calibration at 100 Hz (traceable to NIST)-1
    (M) metric mounting
    equipment
    M080A159Amounting bolts 1/2 "20 M6 x 1-1
    (TO) temperature output
    temperature range36 … 250 ° F2 … 121 ° C"
    Transcription factor5.56 mV / ° F
    (zero point at 32 °F)
    10 mV / ° C
    Electrical connectionpotted integrated cable
    connections (red wire)acceleration output
    (Black wire) pin assigNmentmass
    pin assigNment (white wire)temperature output
    (EX) with ATEX approved
    approval for use in potentially explosive atmospheresExIA IIC T4, AExia IIC, T4
    approval for use in potentially explosive atmospheresEEx nL IIC T4,-40 ° C ≤ Ta ≤ 121 ° C, II 1 G
    approval for use in potentially explosive atmospheresCL I, div I, groups A, B, C, D CL
    II, div I, groups E, F, G Cl
    III, div I
    Approval for use in potentially explosive atmospheresCL I, div 2, groups A, B, C, D
    ExnL IIC T4, AExnA IIC T4
    approval for potentially explosive atmospheresEEx nL IIC T4,-40 ° C ≤ Ta ≤ 121 ° C, II 3 G

    4 other articles of the same category: