PCB-(M)602D02
basic data | |||
sensitivity (±20%) | 500 mV / g | 51.0 mV/(m/s²) | [5] |
measuring range | ± 10 g | ±98 m / s² | |
Frequency range (± 3 dB) | 30 … 180,000 cpm | 0.5 … 3,000 Hz | [2] |
resonance frequency | 1,500 kcpm | 25,000 Hz | [1] |
Wide band resolution | 300 µg | 2,941 µm / s ² | [1] |
linearity | ≤1% | [3] | |
Transverse acceleration sensitivity | ≤ 7% | ||
conditions of use | |||
Overload limit (shock) | 5,000 g pk | 49,050 m/s² pk | |
temperature range | -65 … 250 ° F | -54 … 121 ° C | |
Type of protection | IP68 | ||
Technical characteristics | |||
settling time (on bias voltage ± 1%) | ≤5.0 s | ||
discharging charging time constant | ≥0.3 s | ||
Power | 18 … 28 V DC | ||
constant power supply | 2 … 20 mA | ||
Output impedance | < 500 Ω | ||
Bias voltage | 8 … 12 V DC | ||
Spectral noise (10 Hz) | 8 µg / √Hz | 78.5 (µm / s ²) / √Hz | [1] |
spectral noise (100 Hz) | 3 µg / √Hz | 29.4 (µm / s ²) / √Hz | [1] |
spectral noise (1,000 Hz) | 3 µg / √Hz | 29.4 (µm / s ²) / √Hz | [1] |
electric Insulation (housing) | |||
physical properties | |||
size - length | 1.65 in | 41.9 mm | |
Gr size - width | 0.74 at | 18.8 mm | |
size - height | 0,845 in | 21.5 mm | |
mass | 2.61 oz | 74.0 grams | |
Mounting thread | 1/4"-28 | No metric equivalent | [4] |
Assembly torque | 2 … 5 ft-lb | 2.7 … 6.8 Nm | |
sensor element | ceramic | ||
geometry of the Sensor element | shear principle | ||
housing material | stainless steel | ||
sealing | hermetically sealed welded | ||
Electrical connection | 2-pin connector (MIL-C-5015) | ||
connection position | side | ||
notes | |||
[1] | typically | ||
[2] | the upper cut-off frequency tolerance: ±10% | ||
[3] | zero-based balancing line, determined using the method of least squares | ||
[4] | mounting with M6 screw possible | ||
[5] | Conversion factor 1 g = 9.81 m/s² | ||
[6] | details: see PCBs Declaration of conformance PS023 and PS060 | ||
equipment | |||
081A97 | passage screw 1/4 "28 | -1 | |
ICS-2 | single point calibration at 100 Hz" (traceable to NIST) | -1 | |
(M) metric mounting | |||
equipment | |||
M081A97 | metric mounting bolt with M6 thread | -1 | |
(EX) with ATEX approval | |||
Approval for use in potentially explosive atmospheres | EEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 3 G | ||
Approval for use in potentially explosive atmospheres | EEx ia IIC T4,-40 ° C≤Ta≤121 ° C, II 1 G | ||
approved for explosive atmosphere eras | CL I, div I, groups A, B, C, D CL II, div I, groups E, F, G Cl III, div I | ||
approval for use in potentially explosive atmospheres | ExIA IIC T4, AExia IIC, T4 | ||
Approval for use in potentially explosive atmospheres | CL I, div 2, groups A, B, C, D ExnL IIC T4, AExnA IIC T4 |