PCB-352M212
    zoom_out_map

      PCB-352M212

    • ICP®-miniature vibration sensor for vacuum applications,
    • Low outgassing
    • Measuring range 500 g
    • Sensitivity 10 mV / g,
    • Frequency range 0.5 … 10,000 Hz,
    • Mass 0.64 grams,
    • Integrated cable, length 3 m,
      ending on 10-32 plug
    • basic data
      sensitivity (±15%)10 mV / g1.02 mV/(m/s²)
      range±500 g pk ±4. 900 m/s² pk
      frequency range (±5%)0.5 … 10,000 Hz
      Frequency range (± 10%)0.35 … 16,000 Hz
      frequency range (± 3 dB)0.2 … 25,000 Hz
      Resonance frequency≥ 65,000 Hz
      wide band resolution0.003 g RMS0.03 m/s² RMS[1]
      Linearity≤ 1%[2]
      transverse acceleration sensitivity≤ 5%
      conditions of use
      (Shock) overload limit± 10.000 g pk±98. 000 m/s² pk
      Temperature range (operation)-65 … 250 ° F-54 … 121 ° C
      Specifications
      power supply18 … 30 V DC
      Constant power supply2 … 20 mA
      output impedance≤200Ω
      Bias voltage7 … 11 V DC
      Discharging charging time constant1.0 … 3<5 s
      settling time < br(auf Bias-Spannung ±10 %)≤ 3 s
      Spectral noise725 µg / √ Hz7.110 (µm / s ²) / √ Hz[1]
      spectral noise (10 Hz)225 µg / √ Hz2.210 (µ m/s²) / √ Hz[1]
      spectral noise (100 Hz)60 µg / √ Hz590 (µm / s ²) / √ Hz[1]
      spectral noise (1,000 Hz)20 µg / √ Hz196 (µm / s ²) / √ Hz[1]
      physical properties
      Size - height0.14 in3.6 mm
      dimensions (without cable)0.023 oz0.64 grams[1]
      sensor elementceramic
      Geometry of the sensor elementshear principle
      housing materialtitanium
      Sealinghermetically sealed
      size - length0.41 in10.4 mm
      size - width0.25 in6.4 mm
      electrical connectorpins soldered cable
      cable exitside
      Cable termination10-32-coaxial connectors
      Cable length10 ft3 m
      cable typetwisted pair of yp 089,
      mountingBonding
      notes
      [1]typically
      [2]zero-based balancing line, determined with the methodthe least squares
      equipment
      039A32transfer tool for the model 352 M 212-1
      080A109Mount wax-1
      ACS-1frequency response, traceable to NIST (10 Hz up to the upper 5% point)-1
      PCB-352M212

      Specific References

      Download

      352M212_drawing.PDF

      Technical drawing

      Download (852.67k)

      352M212_manual.PDF

      Operating instructions

      Download (2.42M)

      352M212_specs.PDF

      Technical data sheet

      Download (31.18k)