PCB-(M)108A02

PCB-(M)108A02

  • ICP® pressure sensor with ceramic-coated Cone,
  • For hydraulic applications,
  • Measuring range 68.950 kPa,
  • Sensitivity 0.073 mV / kPa,
  • Lower limiting frequency 0.01 Hz,
  • 10-32 female connector

basic data
Measurement range (output range ± 5 V)10,000 psi68,950 kPa
Usable overload range (output range is ± 10 V)20,000 psi137,900 kPa[1]
Sensitivity (± 15%)0.5 mV / psi0.073 mV / kPa
Maximum static pressure50,000 psi344,750 kPa
resolution0.2 psi1.4 kPa
resonant frequency≥250.000 Hz
Rise time (reflected pressure)≤2 microseconds
Lower limit frequency (-5%)0.01 Hz
linearity error≤2% FS[2]
Operating conditions
acceleration sensitivity?0,05 psi / g?0,035 kPa / (m / s)
The temperature range (operation)-100 ... 275 ° F-73 ... 135 ° C
Temperature coefficient of sensitivity?0,10% / ° F?0,18% / ° C
maximum acceleration2000 g pk19,614 m / spk
Maximum shock resistance20,000 g pk196,140 m / s pk
Technical characteristics
Output polarity (positive pressure)positive
Discharging time (at room temperature)?50 s
supply voltage20 ... 30 V DC
Constant current supply2 ... 20 mA
output impedance≤100 Ω
Bias voltage8 ... 14 V DC
physical properties
Geometry of the sensor elementcompression principle
sensor elementquartz
housing materialC-300
membraneC-300
sealHermetically sealed
electrical connection10-32 coaxial
Dimensions0.42 oz12 grams
Hints
[1]For an output range up to 10 V, the supply voltage at least 24 V has to DC , respectively. At low bias voltage of the sensor, no negative output range up to -10 V can be used.
[2]Zero-based line of best fit, determined by the method of least squares
[3]Details: see PCB Declaration of Conformance PS023
included supply
065A06Seal ring, 0.318 "outside x 0.250" x 0.010 inner "high, 316L (stainless steel)-3
(M) Metric assembly

2 other articles of the same category: