PCB-VO(M)622A11
    zoom_out_map

      PCB-VO(M)622A11

    • Industrial ICP® vibration sensor,
    • With vibration velocity output
    • Measuring range 1.27 m/s,
    • Sensitivity 3.9 V/(m/s),
    • Frequency range 3 … 9,000 Hz,
    • Frequency response calibration,
    • Integrated cable, length 3 m,
      ending on cut end
    • basic data
      sensitivity (±10%)≥ 100 MΩ/(in/s)3,937 mV/(m/s)[1]
      range±50 in / s± 1, 27 m/s
      Frequency range (± 10%)240 … 270,000 cpm4 … 4,500 Hz[5] [6]
      frequency range (± 3 dB)180 … 540,000 cpm3 … 9,000 Hz
      resonance frequency1.200 kcpm20,000 Hz[2]
      wide band resolution450 µin/s11.4 µm/s[2]
      Linearity≤1%[3]
      transverse acceleration sensitivity≤ 5%
      conditions of use
      5,000 g pk49,050 m/s² pkOverload limit (shock)
      Temperature range-65 … 250 ° F-54 … 121 ° C
      technical properties
      settling time (on bias voltage ± 1%)≤ 30 seconds
      Power18… 28 V DC
      constant power supply2 … 10 mA
      output impedance< 100 Ω
      Bias voltage8 … 12 V DC
      spectral noise (10 Hz)40 µin/sec /. √ Hz1.12 µm/sec / √ Hz[2]
      spectral noise (100 Hz)7.0 µin/sec / √ Hz0.18 µm/sec / √ Hz[2]
      Spectral noise (1,000 Hz)0.4 µin/sec / √ Hz0.01 µm/sec / √ Hz[2]
      electrical protectionRFI/ESD
      Electrical insulation≥ 100 MΩ
      physical properties
      size - hex7/8 in22 mm
      size ße - height4.3 in109 mm
      mass3.3 oz94 grams
      mounting thread1/4 "-28 threaded[4]"
      Assembly torque2 … 5 ft-lb2.7 … 6.8 Nm
      sensor elementceramic
      geometry of the sensor elementShear principle
      housing materialstainless steel
      sealinghermetically sealed welded
      Cable length10 ft3 m
      cable typepolyurethane[7]
      notes
      [1] Conversion factor 1 g = 9.81 m/s²
      [2]typically
      [3]zero-based balancing line, determined with the method of least squares
      [4]no equivalent in SI units
      [5]1 Hz 60 = cpm ("Cycles Per Minute": revolutions per minute) ).
      [6]the upper cut-off frequency tolerance: ±10%
      [7]Screened two-wire cable with twisted wire
      [8]Details: see PCBs Declaration of conformance PS023 and PS061
      equipment
      081A40 Mounting bolts with 1/4 "-28 thread-1
      ICS-1frequency response for uniaxial sensors from 10 Hz up to the upper 5% frequency-1
      (M) metric montage"
      Equipment
      M081A61metric mounting bolts with M6 thread-1
      (TO) temperature output
      Temperature range36 … 250 ° F2 … 121 ° C
      Transcription factor5.56 mV / ° F
      (zero point at 32 °F)
      10 mV / ° C
      electrical connection3-Pin
      Pin assigNment (PIN A)acceleration output
      pin assigNment (PIN B)dimensions
      Terminal assigNment (PIN C)temperature output
      (EX) with ATEX approval
      approval for use in potentially explosive atmospheresEExIA IIC T4,-54 ° C ≤ Ta ≤ 121 ° C, II 1 G
      (CS) CSA-approved
      approval for use in potentially explosive atmospheresCL I, div I, groups A, B, C, D CL
      II, div I, groups E, F, G
      CL III, div I
      approval for use in potentially explosive atmospheresExIA IIC T4, AExia IIC, T4
      approval for explosionsgef ährdete atmospheresCL I, div 2, groups A, B, C, D
      ExnL IIC T4, AExnA IIC T4
      PCB-VO(M)622A11

      Specific References

      Download

      VO622A11_drawing.PDF

      Technical drawing

      Download (33.96k)

      VO622A11_manual.PDF

      Operating instructions

      Download (823.9k)

      VO622A11_specs.PDF

      Technical data sheet

      Download (89.1k)