PCB-682C03
- Transmitter for mounting on a DIN rail,
- Connection of an industrial ICP® vibration sensor,
- Integrated sensor power supply
basic data | |||
number of channels | 1 | ||
voltage gain | 1x / 10x / 100x | [1] | |
Frequency range (± 1 dB) | 60 ... 6,000,000 cpm | 1 ... 100 000 Hz | [2] |
linearity error | ?2% | ||
Operating conditions | |||
temperature range | 32 ... 158 ° F | 0 ... 70 ° C | |
Technical characteristics | |||
care | DC | ||
Voltage (± 10%) | 24 V DC | ||
current consumption | ?60 mA | ||
Supply voltage (± 1 V DC ) (for Sensor) | 18 V DC | [3] | |
Constant current supply (for Sensor) | 4.10 mA | [1] | |
Spectral noise (10 Hz) | 0.8 uV / Hz | [7] [5] | |
Spectral noise (100 Hz) | 0.5 µV/ ?Hz | [7] [5] | |
Spectral noise (1,000 Hz) | 0.5 µV/ ?Hz | [7] [5] | |
Spectral noise (10,000 Hz) | 0.6 uV / Hz | [7] [5] | |
Broadband noise (1 ... 10,000 Hz) | 50 uV | [7] [5] | |
Spectral noise (10 Hz) | 7.5 uV / Hz | [6] [5] | |
Spectral noise (100 Hz) | 3.6 µV/ ?Hz | [6] [5] | |
Spectral noise (1,000 Hz) | 3.2 uV / Hz | [6] [5] | |
Spectral noise (10,000 Hz) | 6.0 uV / Hz | [6] [5] | |
Broadband noise (1 ... 10,000 Hz) | 400 uV | [6] [5] | |
Spectral noise (10 Hz) | 80 µV/ ?Hz | [4] [5] | |
Spectral noise (100 Hz) | 40 uV / Hz | [4] [5] | |
Spectral noise (1,000 Hz) | 32 µV/ ?Hz | [4] [5] | |
Spectral noise (10,000 Hz) | 50 µV/ ?Hz | [4] [5] | |
Broadband noise (1 ... 10,000 Hz) | 3.5 mV | [4] [5] | |
fuse | 0.0416666666666667 | ||
physical properties | |||
Connection (ICP sensor input) | terminals | ||
Terminal (output) | terminals | ||
Connector (DC power supply) | terminals | ||
Assembly | on DIN rail | ||
Size - Height | 3.1 in | 78.7 mm | |
Size - Width | 0.97 in | 24.6 mm | |
Size - Depth | 3.3 in | 83.8 mm | |
Dimensions | 0.194 lb | 0.088 kg | |
Hints | |||
[1] | Adjustable via internal jumpers | ||
[2] | 1 Hz = 60 cpm ( "Cycles Per Minute": revolutions per minute) | ||
[3] | The bias voltage of the connected sensor should be at most 13 V DC be, since otherwise the positive measurement range is reduced, or the sensor is not working. | ||
[4] | Gain 100 | ||
[5] | typically, | ||
[6] | Gain 10 | ||
[7] | Gain 1 | ||
additional information | |||
entrance | ICP sensor | ||
outputs | Real-time signal, gain 1x / 10x / 100x, range ± 6 V | ||
application | ICP® sensor supply |