PCB-3713E112G

PCB-3713E112G

  • Triaxial MEMS accelerometer,
  • Suitable for measuring static accelerations,
  • Measurement range 2 g,
  • Sensitivity 1,000 mV / g,
  • Typical frequency range 0 … 400 Hz,
  • Supply voltage 6 … 30 V DC,
  • 9-pin female connector on the side
  • basic data
    sensitivity (±3%)1,000 mV / g101.9 mV/(m/s²)[1]
     
    measuring range±2 g pkpk ±19, 6 m/s² 
     
    Frequency range (± 3 dB)0 … 400 Hz [2]
     
    frequency range (± 3 dB)0 …200 Hz [5]
     
    Phase error< 2,5 °  
     
    wide band resolution (0,5 … 100 Hz)[2]0.001 m/s² rmsrms 0.1 mg
     
    Linearity error≤1% [3] [4]
     
    transverse acceleration sensitivity≤5%  
    conditions of use
    Overload limit (shock)±2. 000 g pk±19. 620 m / pk 
     
    Temperature range (operation)-65 … 250 ° F-54 … 121 ° C 
     
    temperature range (storage)-65 … 250 ° F-54 … 121 ° C 
     
    Temperature coefficient of sensitivity≤5% [6]
     
    Temperature coefficient of sensitivity the zero point±4% FSO [6] [3]
     
    strain sensitivity (footprint)0.001 g/µε0.01 (m/s²)/µε[] 2]
     
    magnetic sensitivity100µg/Gs/9.8 (m/s²) / T[2]
    technical specifications
    power supply6 … 30 V DC  
     
    Power? 30 mA  
     
    output impedance? 120 ?  
     
    Spannungsoffset±160 mV DC [7]
     
    spectral noise (1 … 100 Hz)10 µg / √Hz98.1 (µm / s ²) / √Hz[2]
     
    electrical insulation (base)>100 MΩ  
    physical properties
    housing materialtitanium  
     
    Sealinghermetically sealed  
     
    size - length0.85 in21.6 mm 
     
    Size - width0.85 in21.6 mm 
     
    size - height0.85 in21.6 mm 
     
    weight0.8 oz22.7 grams 
     
    Electrical connector9-Pin  
     
    connectionon the side  
     
    mounting thread10-32 female  
    notes
    [1]measured at 100 Hz  
     
    [2]typically  
     
    [3]FSO = "Full Scale Output": maximum output signal of the measuring range (4 V DC).  
     
    [4]zero-based balancing line, determined using the method of least squares  
     
    [5]guaranteed; through supplied with Calibration certificate is  
     
    [6]-54 … 121 ° C, reference 24 ° C  
     
    [7]offset at 3 meters cable length (type 037)  
     
    [8]details: see PCB Declaration of conformance PS027  
    equipment
    080A12adhesive mounting-1 
     
    081 B 05mounting bolts, 10-32 on 10-32-1 
     
    M081B05mounting bolts, 10-32 to M6 x 0.75-1 
     
    ACS-145 Tcalibration of amplitude and phase of 2 Hz up to the upper ±3dB point ?200 ?z)-1 