PCB-3713E1125G
basic data | |||
sensitivity (±3%) | 80 mV / g | 8.15 mV/(m/s²) | [1] |
measuring range | ±25 g pk | pk ±245, 2 m/s² | |
Frequency range (± 3 dB) | 0 … 1500 Hz | [2] | |
frequency range (± 3 dB) | 0 … 750 Hz | [5] | |
Phase error | < 10 ° | ||
wide band resolution (0,5 … 100 Hz) | [2] | 0.003 m/s² rms | rms 0.3 mg |
Linearity error | ≤ 1% | [3] [4] | |
transverse acceleration sensitivity | ≤ 5% | ||
conditions of use | |||
Overload limit (shock) | ±5. 000 g pk | ±49. 050 m / pk | |
Temperature range (operation) | -65 … 250 ° F | -54 … 121 ° C | |
temperature range (storage) | -65 … 250 ° F | -54 … 121 ° C | |
Temperature coefficient of sensitivity | ±3% | [6] | |
temperature coefficientzero | ±2% FSO | [6] [3] | |
strain sensitivity (footprint) | 0.001 g/µε | 0.01 (m/s²)/µε | [2] |
Magnetic sensitivity | 100 | µg/Gs/9.8 (m/s²) / T | [2] |
technical specifications | |||
power supply | 6 … 30 V DC | ||
Power | ≤ 30 mA | ||
output impedance | ≤ 120 Ω | ||
Spannungsoffset | ±80 mV DC | [7] | |
spectral noise (1 … 100 Hz) | 100 µg / √ Hz | 981 (µm / s ²) ) / √ Hz | [2] |
electrical insulation (base) | ≥ 100 MΩ | ||
physical properties | |||
housing material | titanium | ||
Sealing | hermetically sealed | ||
size - length | 0.85 in | 21.6 mm | |
Gr size - width | 0.85in | 21.6 mm | |
size - height | 0.85 in | 21.6 mm | |
weight | 0.8 oz | 22.7 grams | |
Electrical connector | 9-Pin | ||
Connection | on the side | ||
mounting thread | 10-32 female | ||
notes | |||
[1] | measured @ 100 Hz | ||
[2] | typically | ||
[3] | FSO = "Full Scale Output": maximum output (4 V measuring range ( DC). | ||
[4] | zero-based balancing line, determined using the method of least squares | ||
[5] | guaranteed; through supplied with Calibration certificate is | ||
[6] | -54 … 121 ° C, reference 24 ° C | ||
[7] | offset at 3 meters cable length (type 037) | ||
[8] | details: see PCB Declarationof conformance PS027 | ||
equipment | |||
080A12 | adhesive mounting | -1 | |
081 B 05 | Mounting bolts, 10-32 on 10-32 | -1 | |
M081B05 | mounting bolts, 10-32 to M6 x 0.75 | -1 | |
ACS-145 T | calibration of amplitude and phase response from 2 Hz to the upper ±3dB point (750 Hz) | -1 |