PCB-3713B12200G
    zoom_out_map

      PCB-3713B12200G

      • Triaxial MEMS accelerometer,
      • Suitable for measuring static accelerations,
      • Measuring range 200 g
      • Sensitivity 10 mV / g,
      • Frequency range 0 … 850 Hz,
      • Supply voltage 6 … 30 V DC,
      • Integrated cable, length 3 m, ending on stripped and tinned ends
      basic data
      Sensitivity (± 10%)10 mV / g1.0 mV / (m / s)[1]
      measuring range± 200 g pk± 1962.0 m / s pk
      Frequency range (± 5%)0 ... 850 Hz
      Frequency range (± 10%)0 ... 1250 Hz
      resonant frequency?11.000 Hz
      Phase response (100 Hz)<10 °
      Broadband resolution21.1 mg rms0.21 m / s RMS[2]
      linearity error≤1%[3]
      Lateral acceleration sensitivity?3%
      Operating conditions
      Overload limit (shock)± 3.000 g pk± 29,420 m / s² pk
      The temperature range (operation)-65 ... 250 ° F-54 ... 121 ° C
      Temperature range (storage)-65 ... 250 ° F-54 ... 121 ° C
      Temperature coefficient of sensitivity± 3%[4]
      Temperature coefficient of the zero point± 2% FSO[4] [5]
      Strain sensitivity (base surface)0.0005 g / µε0,005 (m / s²) / µε[2]
      magnetic sensitivity70 ug / µε6.9 (m / s²) / T[2]
      Technical characteristics
      supply voltage6 ... 30 V DC
      current consumption?6 mA
      output impedance≤100 Ω
      voltage offset± 40 mV DC[6]
      Spectral Noise (1)2518 µg/√Hz24,693 (µm/s²)/√Hz[2]
      Electrical insulation (housing)> 100 M
      physical properties
      housing materialtitanium
      sealhermetically sealed
      Size - Length0.8 in20.3 mm
      Size - Width0.8 in20.3 mm
      Size - Height0.8 in20.3 mm
      Mass (wired)4.2 oz119 grams
      electrical connectionintegrated cable
      cable outletLaterally
      cable typeType 037, shielded 10-wire cable
      cable length10 ft3 m
      mounting thread10-32 female thread
      Hints
      [1]Measured at 100 Hz, 10 g RMS
      [2]typically,
      [3]Zero-based line of best fit, determined by the method of least squares
      [4]-54 ... 121 ° C, Reference 24 ° C
      [5]FSO = "Full Scale Output": maximum output signal over the measuring area (4 V DC ).
      [6]Offset at 3 meter cable (type 037)
      [7]Details: see PCB Declaration of Conformance PS027
      included supply
      080A12adhesive mounting-1
      081B05Mounting bolts (10-32 to 10-32)-1
      ACS 103TCalibration of the amplitude and phase response of 2 Hz to the upper 5% -frequency for triaxial transducer-1
      M081B05Mounting bolts 10-32 on M6 x 0.75-1
      PCB-3713B12200G

      Specific References

      Download

      3713B12200G_drawing.PDF

      Technical drawing

      Download (316.17k)

      3713B12200G_manual.PDF

      Operating instructions

      Download (983.63k)

      3713B12200G_specs.PDF

      Technical data sheet