PCB-3711B11200G

PCB-3711B11200G

  • MEMS-DC acceleration sensor,
  • Suitable for measuring static accelerations,
  • Measuring range 200 g
  • Sensitivity 10 mV / g,
  • Frequency range 0 … 850 Hz,
  • Supply voltage 6 … 30 V DC,
  • 4-pin female connector on the side
  • basic data
    sensitivity (±10%)10 mV / g1.02 mV/(m/s²) 
     
    range±200 gpk±1. 960 m/s² pk 
     
    frequency range (±5%)0 … 850 Hz  
     
    Frequency range (± 10%)0 … 1.250 Hz  
     
    resonance frequency≥11,000 Hz  
     
    phase response (100 Hz)< 10 °  
     
    wide band resolution21.1 mg rms0.21 m/s² RMS[3]
     
    Linearitä avoidable≤1% [2]
     
    transverse acceleration sensitivity≤3%  
    conditions of use
    Overload limit (shock)±3. 000 g pk±29. 420 m/s² pk 
     
    Temperature range (operation)-65 … 250 ° F-54 …121 ° C 
     
    temperature range (storage)-65 … 250 ° F-54 … 121 ° C 
     
    Temperature coefficient of sensitivity≤3% [1]
     
    Temperature coefficient of sensitivity the zero point±2% FSO [1] [4]
     
    strain sensitivity (base area)0.0005 g/µε0.005 (m/s²)/µε[3]
     
    magnetic sensitivity70µg/Gs/6.9 (m/s²) / T[3]
    technical characteristics
    Supply6 … 30 V DC  
     
    power≤6 mA  
     
    Output impedance≤100 Ω  
     
    Spannungsoffset40 … 40 mV DC [5]
     
    spectral noise (1)2.518 µg / √Hz24.693 (µm / s ²) / √Hz[3]
     
    electrical insulation (housing)>100 MΩ  
    physical properties
    Housing materialtitanium  
     
    sealedsealedclose  
     
    size - height0.45 in11.4 mm 
     
    size - length0.85 in21.6 mm 
     
    Size - width0.85 in21.6 mm 
     
    mass0.58 oz16.3 grams 
     
    wiring4-pin  
     
    Connection positionside  
     
    mountinghole  
    notes
    [1]-54 … 121 ° C, reference 24 ° C  
     
    [2]zero-based balancing line, determined using the method of least squares  
     
    [3]typically  
     
    [4]FSO = "Full Scale Output": maximum output signal of the measuring range (4 V DC).  
     
    [5]offset at 3 meters cable length (type 010)  
     
    [6]details: see PCB Declarationof conformance PS027  
    equipment
    080A152mounting clip-1 
     
    081A113mounting screw2 
     
    ACS-103calibration of amplitude and phase response of 2 Hz up to the upper 5% frequency-1 
     
    M081A113metric mounting screw2 