PCB-353B33

PCB-353B33

  • ICP® vibration sensor,
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 1... 4,000 Hz,
  • 10-32 socket side

basic data
Sensitivity (± 5%)100 mV / g10.19 mV / (m / s)[1]
measuring range± 50 g pk± 491 m / s pk
Frequency range (± 5%)1 ... 4000 Hz
Frequency range (± 10%)0.7 ... 6500 Hz
Frequency range (± 3 dB)0.35 ... 12,000 Hz
resonant frequency≥22.000 Hz
Broadband resolution0.0005 g RMS0.005 m / s RMS[4]
linearity error≤1%[2]
Lateral acceleration sensitivity≤5%[3]
Operating conditions
Overload limit (shock)± 10,000 g pk± 98,100 m / s² pk
The temperature range (operation)-65 ... 250 ° F-54 ... 121 ° C
Strain sensitivity (base surface)0.0002 g / µε0,002 (m / s²) / µε[4]
Technical characteristics
supply voltage18 ... 30 V DC
Constant current supply2 ... 20 mA
output impedance≤100 Ω
Bias voltage7.5 ... 11.5 V DC
discharging0.5 ... 2.0 s
Settling time 
(on the bias voltage ± 10%)
<25 s
Spectral Noise (1 Hz)320 µg/√Hz3,139 (µm/s²)/√Hz[4]
Spectral noise (10 Hz)70 µg/√Hz687 (µm/s²)/√Hz[4]
Spectral noise (100 Hz)18 µg/√Hz177 (µm/s²)/√Hz[4]
Spectral noise (1,000 Hz)6.4 µg/√Hz63 (µm/s²)/√Hz[4]
physical properties
Size - Height0.93 in23.6 mm
Size - Hexagon0.75 in19.1 mm
Dimensions0.95 oz27 grams[4]
sensor elementquartz
Geometry of the sensor elementshear principle
housing materialtitanium
sealHermetically sealed
electrical connection10-32 coaxial
port locationLaterally
mounting thread10-32 female thread
Hints
[1]Sensitivity tolerance for sensors with B or Q-Option: ± 10%
[2]Zero-based line of best fit, determined by the method of least squares
[3]Lateral acceleration sensitivity typically ≤ 3%
[4]typically,
[5]Details: see PCB Declaration of Conformance PS023
included supply
080A109mounting wax-1
080A12adhesive mounting-1
081B05Mounting bolts (10-32 to 10-32)-1
ACS-1Frequency response, traceable to NIST (10 Hz up to the top 5% point)-1
M081B05Mounting bolts 10-32 on M6 x 0.75-1
(Q) Increased discharge time
Frequency range (± 5%)0.1 ... 4,000 Hz
Frequency range (± 10%)0.07 ... 6500 Hz
discharging?10 s
settling<120 s
included supply
ACS-4Low frequency calibration (phase and amplitude) of 0.5 ... 10 Hz-1
(B) Reduced bias voltage
Bias voltage4.5 ... 7.5 V DC
supply voltage12 ... 30 V DC
Constant current supply1 ... 20 mA
measuring range30 g pk294 m / s pk
(J) ground isolation
Frequency range (± 5%)1 ... 4000 Hz
Frequency range (± 10%)0.7 ... 6000 Hz
resonant frequency18,000 Hz
electrical insulation?100 milliohms
Size - Hexagon0.75 in19.1 mm
Size - Height0.98 in24.9 mm
(W) Waterproof cable connection
port locationLaterally

22 other articles of the same category: