PCB-353B04

PCB-353B04

  • ICP® vibration sensor,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,.
  • Frequency range 1... 7,000 Hz,
  • 10-32 female connector above

basic data
Sensitivity (± 5%)10 mV / g1.02 mV / (m / s)[1]
measuring range± 500 g pk± 4,905 m / s² pk
Frequency range (± 5%)1 ... 7000 Hz
Frequency range (± 10%)0.7 ... 11,000 Hz
Frequency range (± 3 dB)0.35 ... 20,000 Hz
resonant frequency≥38.000 Hz
Broadband resolution0.003 g RMS0.03 m / s RMS[4]
linearity error≤1%[2]
Lateral acceleration sensitivity≤5%[3]
Operating conditions
Overload limit (shock)± 10,000 g pk± 98,100 m / s² pk
The temperature range (operation)-65 ... 250 ° F-54 ... 121 ° C
Strain sensitivity (base surface)≤0,0005 g /µε≤0,005 (m / s²) / µε[4]
Technical characteristics
supply voltage18 ... 30 V DC
Constant current supply2 ... 20 mA
output impedance≤100 Ω
Bias voltage8 ... 12 V DC
discharging0.5 ... 2.6 s
Settling time 
(on the bias voltage ± 10%)
<5 s
Spectral Noise (1 Hz)2800 µg/√Hz27,468 (µm/s²)/√Hz[4]
Spectral noise (10 Hz)700 µg/√Hz6,867 (µm/s²)/√Hz[4]
Spectral noise (100 Hz)180 µg/√Hz1,766 (µm/s²)/√Hz[4]
Spectral noise (1,000 Hz)64 ug / √Hz628 (µm/s²)/√Hz[4]
physical properties
Size - Height1.14 in29.0 mm
Size - Hexagon0.50 in12.7 mm
Dimensions0.38 oz10.5 grams[4]
sensor elementquartz
Geometry of the sensor elementshear principle
housing materialtitanium
sealHermetically sealed
electrical connection10-32 coaxial
port locationAbove
mounting thread10-32 female thread
Hints
[1]Sensitivity tolerance for sensors with B or Q-Option: ± 10%
[2]Zero-based line of best fit, determined by the method of least squares
[3]Lateral acceleration sensitivity typically ≤ 3%
[4]typically,
[5]Details: see PCB Declaration of Conformance PS023
included supply
080Aadhesive mounting-1
080A109mounting wax-1
081B05Mounting bolts (10-32 to 10-32)-1
ACS-1Frequency response, traceable to NIST (10 Hz up to the top 5% point)-1
M081B05Mounting bolts 10-32 on M6 x 0.75-1
(Q) Increased discharge time
Frequency range (± 5%)0.1 ... 7000 Hz
Frequency range (± 10%)0.07 ... 11,000 Hz
discharging> 10 s
settling45 s
included supply
ACS-4Low frequency calibration (phase and amplitude) of 0.5 ... 10 Hz-1
(B) Reduced bias voltage
Bias voltage4.5 ... 7.5 V DC
supply voltage12 ... 30 V DC
Constant current supply1 ... 20 mA
measuring range300 g pk2,943 m / s pk
(J) ground isolation
Frequency range (± 5%)1 ... 5000 Hz
Frequency range (± 10%)0.7 ... 9000 Hz
resonant frequency22,000 Hz
electrical insulation?100 milliohms
Size - Hexagon0.50 in12.7 mm
Size - Height1.19 in30.2 mm
(W) Waterproof cable connection
port locationAbove