PCB-353B02

PCB-353B02

  • ICP® vibration sensor,
  • Range 250 g,
  • Sensitivity 20 mV / g,
  • Frequency range 1 … 7,000 Hz,
  • 10-32 female connector above
  • basic data
    sensitivity (±5%)20 mV / g2.04 mV/(m/s²)[2]
    range±250 g PK±2. 453 m/s² pk
    frequency range (±5%)1 … 7,000 Hz
    Frequency range (± 10%)0.7 … 10,000 Hz
    frequency range (± 3 dB)0.35 … 18,000 Hz
    Resonance frequency&ge≥38,000 Hz
    wide band resolution0.003 g RMS0.03 m/s² RMS[1]
    Linearity≤ 1%[3]
    transverse acceleration sensitivity≤ 5%[4]
    conditions of use
    (Shock) overload limit± 10.000 g pk ±98.100 m/s² pk
    Temperature range (operation)-65 … 250 ° F-54 … 121 ° C
    Strain sensitivity (base area)≤ 0.0005 g/µε≤ 0.005 (m/s²)/µε[1]
    technical characteristics
    Supply voltage18 … 30 V DC
    constant power supply2 … 20 mA
    Output impedance≤ 100 Ω
    Bias voltage8 … 12 V DC
    discharging charging time constant0.5 … 2.6 s
    Settling time < br(auf Bias-Spannung ±10 %)<5 s
    spectral noise (1 Hz)1,600 µg / √ Hz15,700 (µm / s ²) / √ Hz[1]
    spectral noise (10 Hz)350 µg / √ Hz3.433 (µm / s ²) / √ Hz[1]
    spectral noise (100 Hz)90 µg /. √ Hz883 (µm / s ²) / √ Hz[1]
    Spectral noise (1,000 Hz)32 µg / √ Hz314 (µm / s ²) / √ Hz[1]
    Physical properties
    Size - height1.19 in30.2 mm
    Size - hex0.50 in12.7 mm
    weight0.35 oz10 grams[1]
    sensor elementquartz
    Geometry of the sensor elementshear principle
    housing materialtitanium
    SealingHermetically sealed welded
    Electrical connection10-32-coaxial socket
    connection positionabove
    Mounting thread10-32 female thread
    notes
    [1]typically
    [2]sensitivity tolerance for sensors with B or Q option: ±10%
    [3]zero-based balancing line, determined using the method of least squares
    [4]transverse acceleration sensitivity typically ≤ 3%
    [5]details: see PCBs Declaration of conformance PS023
    Accessories
    080Aadhesive mounting-1
    080A109mounting wax-1
    081 B 05mounting bolts (10-32 on 10-32)-1
    ACS-1frequency response, traceable to NIST (10 Hz up to the upper 5% point)-1
    M081B05Mounting bolts 10-32 to M6 x 0.75-1
    (Q) increased discharge charge time constant
    frequency range (±5%)0.1 … 7,000 Hz
    frequency range (± 10%)0.07 … 10,000 Hz
    discharging charging time constant> 10 s
    settling time<5 s
    Accessories
    ACS-4low frequency calibration (phase and amplitude) of 0.5 … 10 Hz-1
    (B) reduced bias voltage
    bias voltage4.5 … 7.5 V DC
    power12 … 30 V DC
    Constant power supply1 … 20 mA
    measuring range150 g pk1.418 m/s ² pk
    wide band resolution0.01 g RMS0.1 m/s² RMS
    Spectral noise (1 Hz)2,300 µg / √ Hz22.563 (µm / s ²) / √ Hz
    spectral noise (10 Hz)560 µg / √ Hz5.494 (µm / s ²) / √ Hz
    spectral noise (100 Hz)230 µg / √ Hz2.256 (µm / s ²) / √ Hz
    spectralNoise (1,000 Hz)65 µg / √ Hz638 (µm / s ²) / √ Hz
    (J) mass insulation
    frequency range (±5%)1 … 5,000 Hz
    Frequency range (± 10%)0.7 … 10,000 Hz
    resonance frequency22,000 Hz
    electrical insulation ≥100 MΩ
    size - hex0.50 in12.7 mm
    size - height1.24 in31.5 mm
    (W) waterproof cable connection
    connection positionabove