PCB-352C43

PCB-352C43

  • ICP®-miniature vibration sensor,
  • Masseisoliert,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 1 … 8,000 Hz,
  • Mass of 3 grams,
  • 10-32 female connector above
  • basic data
    sensitivity (±10%)10 mV / g1.02 mV/(m/s²)
    range±500 g pk ±4. 905 m/s 2 pk
    frequency range (±5%)1 … 8,000 Hz
    Frequency range (± 10%)0.5 … 10,000 Hz
    frequency range (± 3 dB)0.3 … 13,000 Hz
    Resonance frequency≥ 30,000 Hz
    wide band resolution0.0008 g RMS0.008 m/s² RMS[3]
    Linearity≤ 1%[1]
    transverse acceleration sensitivity≤ 5%[2]
    conditions of use
    Overload limit±5. 000 g pk±49. 050 m/s² pk
    Temperature range-65… 250 ° F-54 … 121 ° C
    specifications
    power supply22 … 30 V DC
    Constant power supply2 … 20 mA
    output impedance≤200Ω
    bias voltage8 … 15 V DC
    discharging charging time constant0.5 … 2.0 s
    Settling time < br(auf Bias-Spannung ±10 %)< 10 s
    spectral noise (1 Hz)200 µg / √ Hz1,962 (µm / s ²) / √ Hz[3]
    Spectral noise (10 Hz)60 µg / √ Hz589 (µm / s ²) / √ Hz[3]
    spectral noise (100 Hz)15 µg / √ Hz147 (µm / s ²) / √ Hz[3]
    spectral noise (1,000 Hz)8 µg / √ Hz79 (µm / s ²) / √ Hz[3]
    electrical insulation≥ 100 MΩΩ
    Physical properties
    size - height0.42 in10.7 mm
    dimensions0.10 oz3.0 grams[3]
    Sensor elementceramic
    Size - hex0,438 in11.1 mm
    geometry of the sensor elementshear principle
    parts usematerialtitanium
    sealinghermetically sealed welded
    electrical connection10-32-coaxial socket
    Connection positionabove
    attachmentbonding
    notes
    [1]zero-based balancing line, determined using the method of least squares
    [2]transverse acceleration sensitivity typically ≤ 3%
    [3]typically
    [4]details: see PCBs Declaration of conformance PS023
    Accessories
    080A109mounting wax-1
    080A90glue-1
    ACS-1Frequency response, traceable to NIST (10 Hz up to the upper 5% point)-1

    22 other articles of the same category: