PCB-352C03

PCB-352C03

  • ICP® vibration sensor,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,.
  • Frequency range 0.5... 10,000 Hz,
  • 10-32 socket side

 

Basic data
Sensitivity (±10 %)10 mV / g1.02 mV/(m/s²) 
 
Measuring range±500 gPK±4.900 m/s²PK 
 
Frequency range (≤5 %)0.5... 10,000 Hz  
 
Frequency range (±10 %)0.3... 15,000 Hz  
 
Resonance frequency≥50.000 Hz  
 
Wide band resolution0.0005 g RMS0.005 m/s² RMS[1]
 
Linearity error±1 % [2]
 
Transverse acceleration sensitivity≤5 %  
Conditions of use
Overload limit (shock)±5.000 gPK±49.000 m/s²PK 
 
Temperature range (operation)-65... 250 ° F-54... 121 ° C 
 
strain sensitivity (footprint)0,003 g/µε0.029 (m/s²)/µε[1]
specifications
power supply18... 30 V DC  
 
constant power supply2... 20 mA  
 
output impedance100 Ω  
 
Bias voltage7... 12 V DC  
 
discharging charging time constant1.0... 2  
 
settling time
(auf Bias-Spannung ±10 %)
>10s  
 
spectral noise (1 Hz)110 µg/√Hz1,080 (µm/s²)/√Hz 
 
Spectral noise (10 Hz)25 µg/√Hz245 (µm/s²)/√Hz[1]
 
spectral noise (100 Hz)8 µg/√Hz78 (µm/s²)/√Hz[1]
 
Spectral noise (1,000 Hz)4 µg/√Hz39 (µm/s²)/√Hz[1]
Physical properties
Size - height0.62 in15.7 mm 
 
Size - hex0.44 in11.2 mm 
 
Mass0.20 oz5.8 grams[1]
 
Sensor elementCeramic  
 
Geometry of the sensor elementShear principle  
 
Housing materialTitanium  
 
SealingHermetic  
 
Electrical connection10-32-coaxial socket  
 
Connecting positionOn the side  
 
Mounting thread10-32 female thread  
 
Installation torque10... 20 in-lb113... 226 NCM 
Notes
[1]Typically  
 
[2]Zero-balance just, determined using the method of least squares  
 
[3]The data for temperatures above 121 ° C applies only for transducers with HT option.  
 
[4]Details: see PCBs Declaration of conformance PS023  
Included accessories
080AAdhesive mounting-1 
 
080A109Mount wax-1 
 
081B 05Mounting bolts (10-32 on 10-32)-1 
 
ACS-1Frequency response, traceable to NIST (10 Hz up to the upper 5%-Punkt)-1 
 
M081B05Mounting bolts 10-32 to M6 x 0.75-1 
(HT) High temperature electronics
Frequency range (≤5 %)5... 10,000 Hz  
 
Frequency range (±10 %)3... 15,000 Hz  
 
Temperature range-65... 325 ° F-54... 163 ° C 
 
Supply voltage22... 30 V DC  
 
Discharging charging time constant0.1... 0.3 s  
 
spectral noise (1 Hz)1,962 (µm/s²)/√Hz 
 
spectral noise (10 Hz)30 µg/√Hz294 (µm/s²)/√Hz 
 
Bias voltage10... 15 V DC  
 
equipment   
 
ACS-68calibration certificate, traceable to NIST-1 
(J) mass insulation of
frequency range (5%)9,000 Hz  
 
frequency range (10%)14,000 Hz  
 
Resonance frequency40,000 Hz  
 
electrical insulation  
 
size - hex0.44 in11.2 mm 
 
size - height0.67 in17.0 mm 
 
Mass0.21 oz6.0 grams 
(W) waterproof cable connection
Connecting positionOn the side  
(T) TEDS memory in accordance with IEEE PP1451. 4
Temperature range (storage access)-10... 250 ° F-23... 121 ° C 
 
Supply voltage20... 30 V DC  
 
Bias voltage7.5... 13 V DC  
(TLA) TEDS LMS International - free format
Temperature range (storage access)-10... 250 ° F-23... 121 ° C 
 
Supply voltage20... 30 V DC  
 
Bias voltage7.5... 13 V DC  
(TLB) TEDS LMS international - format for the automotive industry
Temperature range (storage access)-10... 250 ° F-23... 121 ° C 
 
Supply voltage20... 30 V < sMall vertical-align.3px = "" >DC  
 
Bias voltage7.5... 13 V DC  
(TLC) TEDS LMS international - format for the aviation industry
Temperature range (storage access)-10... 250 ° F-23... 121 ° C 
 
Supply voltage20... 30 V DC  
 
Bias voltage7.5... 13 V DC  
(TLD) TEDS memory in accordance with IEEE P1451. 4
Temperature range (storage access)-10... 250 ° F-23... 121 ° C 
 
Supply voltage20... 30 V DC  
 
Bias voltage7.5... 13 V DC  

22 other articles of the same category: