PCB-(M)352A60

PCB-(M)352A60

  • ICP® vibration sensor,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 5 … 60,000 Hz,
  • 5-44 female connector above
  • basic data
    sensitivity (±15%)10 mV / g1.02 mV/(m/s²)
    range±500 g pk ±4. 905 m/s 2 pk[1]
    frequency range (± 3 dB)5…60.000 Hz
    Electric filter corner frequency45,000 Hz[5]
    edge steepness of the filter10 dB/decade[5]
    resonance frequency≥ 95,000 Hz
    wide band resolution0.002 g RMS0.02 m/s² RMS [2]
    linearity≤ 1%[3]
    transverse acceleration sensitivity≤ 5%[4]
    Conditions of use
    Overload limit (shock)±5. 000 g pk±49. 050 m/s² pk
    Temperature range-65… 250 ° F-54 … 121 ° C
    strain sensitivity (base area)≤ 0.05 g/µε≤ 0.49 (m/s²)/µε[2]
    Technical characteristics
    Supply voltage18 … 30 V DC
    Constant power supply2 … 20 mA[1]
    output impedance≤ 100 Ω
    Bias voltage8 … 12 V DC
    Discharging charging time constant0.02 … 0.06 s[5]
    spectral noise (10 Hz)160 µg / √ Hz1.570 (µm / s ²) /. √ Hz[2]
    spectral noise (100 Hz)40 µg / √ Hz390 (µm / s ²) / √ Hz[2]
    spectral noise (1,000 Hz)15 µg / √ Hz147 (µm / s ²) / √ Hz[2]
    spectral noise (10,000 Hz)10 µg / √ Hz98 (µm / s ²) / √ Hz[2]
    Physical properties
    size-Height0.81 in21.6 mm
    size - hex3/8 in9.5 mm
    weight0.21 oz6.0 grams[2]
    Sensor elementceramic
    geometry of the sensor elementshear principle
    housing materialStainless steel
    Sealinghermetically sealed welded
    electrical connection5-44 coaxial
    Connection positionabove
    mountingfixed external thread
    mounting thread10-32 male
    Notes
    [1]for cable lengths over 15 meters, the constant current must be at least 6 mA, so that errors are avoided and the full frequency range can be used.
    [2]typically
    [3]zero-based balancing line, determined using the method of least squares
    [4]transverse acceleration sensitivity typically ≤ 3%
    [5]calculated
    [6]details: see PCBs Declaration of conformance PS023
    Accessories
    ACS-52frequency response calibration (UNI-axial) over the entire ±3dB range-1
    (M) metric mounting
    mounting threadM6 x 0.75 male
    (A) glue mounting
    mountingadhesive Assembly
    Mounting threaddoes not exist (bonding)
    size - hex3/8 in9.5 mm
    Gr öße - height0.6817.3
    equipment
    080A90cyano-1

    21 other articles of the same category: