PCB-3711B1250G
    zoom_out_map

      PCB-3711B1250G

    • MEMS accelerometer,
    • Suitable for measuring static accelerations,
    • Measurement range 50 g,
    • Sensitivity 40 mV / g,
    • Frequency range 0 … 1,000 Hz,
    • Supply voltage 6 … 30 V DC,
    • Integrated cable, length 3 m,
      ending on stripped and tinned ends
    • basic data
      sensitivity (±5%)40 mV / g4.1 mV/(m/s²)[1]
       
      range±50 g pk ±490, 3 m/s 2 pk 
       
      frequency range (±5%)0 … 1,000 Hz  
       
      Frequency range (±10)0 … 1500 Hz  
       
      Resonance frequency> 5,100 Hz  
       
      phase response (100 Hz)< 10 °  
       
      wide band resolution5.2 mg rms0.05 m/s² RMS[2]
       
      linearity≤ 1% FS [3]
       
      Transverse acceleration sensitivity≤3%  
      conditions of use
      Overload limit (shock)±3. 000 g pk±29. 420 m/s² pk 
       
      temperature range (operation)-65 … 250 ° F-54.0… 121 ° C 
       
      temperature range (storage)-65 … 250 ° F-54.0 … 121 ° C 
       
      Temperature coefficient of sensitivity the zero point±2, 0% FSO [4] [5]
       
      strain sensitivity (footprint)0.0002 g/µε0.002 (m/s²)/µε[2]
      technical Properties
      supply6 … 30 V DC  
       
      power≤6 mA  
       
      Output impedance≤100 Ω  
       
      Spannungsoffset± 40 mV DC [6]
       
      Spectral noise (1)580 µg / √Hz5.688 (µm / s ²) / √Hz[2]
       
      electrical insulation (housing)>100 MΩ  
      Physical properties
      housing materialanodized aluminum  
       
      waterproofingepoxy resin  
       
      Size - height0,30in7.62 mm 
       
      size - length1.00 in25.4 mm 
       
      size - width0.85 in21.6 mm 
       
      Weight (without cable)0.35 oz9.92 grams[2]
       
      electrical connectionintegrated cable  
       
      cable outletSide  
       
      cable terminationtinned ends  
       
      cord typetype 010, 4-wire shielded cable  
       
      Cable length10 ft3 m 
       
      mountingthrough holes (2)  
      notes
      [1]measured at 100 Hz, 10 g RMS  
       
      [2]typically  
       
      [3]zero-based balancing line, determined using the method of least squares  
       
      [4]FSO = "Full Scale Output": maximum output signal of the measuring range (4 V DC).  
       
      [5]-54 … 121 ° C, reference 24 ° C  
       
      [6]offset at 3 meters cable length (type 010)  
       
      [7 ]Details: see PCBs Declaration of conformance PS027  
      equipment
      081A113Mounting screw2 
       
      ACS-103calibration of amplitude and phase response of 2 Hz up to the upper 5% frequency-1 
       
      M081A113metric Mounting screw2 
      PCB-3711B1250G

      Specific References

      Download

      3711B1250G_drawing.PDF

      Technical drawing

      Download (192.04k)

      3711B1250G_manual.PDF

      Operating instructions

      Download (802.29k)

      3711B1250G_specs.PDF

      Technical data sheet

      Download (443.58k)