PCB-(M)102A07

PCB-(M)102A07

  • ICP® pressure sensor with INVAR-membrane,
  • Masseisoliert,
  • Beschleunigungskompensiert,
  • Measuring range 345 kPa,
  • Sensitivity 14.5 mV / kPa,
  • Lower limiting frequency 0.5 Hz,
  • 10-32 female connector

basic data
Measurement range (output range ± 5 V)50 psi345 kPa
Usable overload range (output range is ± 10 V)100 psi690 kPa[2]
Sensitivity (± 15%)100 mV / psi14.5 mV / kPa
maximum pressure500 psi3447 kPa
resolution0,001 psi0.007 kPa
resonant frequency≥250.000 Hz
rise time≤2 microseconds
Lower limit frequency (-5%)0.5 Hz
linearity error≤1,0% FS[1]
Operating conditions
acceleration sensitivity≤0,002 psi / g≤0,0014 kPa / (m / s)
The temperature range (operation)-100 ... 275 ° F-73 ... 135 ° C
Temperature coefficient of sensitivity≤0,03% / ° F≤0,05% / ° C
Maximum temperature shock (for split second)3000 ° F1650 ° C
Maximum shock resistance20,000 g pk196,000 m / s pk
Technical characteristics
Output polarity (positive pressure)positive
Discharging time (at room temperature)≥1 s
supply voltage20 ... 30 V DC
Constant current supply2 ... 20 mA
output impedance<100 Ω
Bias voltage8 ... 14 V DC
electrical insulation100 M
physical properties
Geometry of the sensor elementcompression principle
sensor elementquartz
housing materialstainless steel
membraneInvar
sealhermetically sealed
electrical connection10-32 coaxial
Dimensions0.39 oz11.0 grams
Hints
[1]Zero-based line of best fit, determined by the method of least squares
[2]For an output range up to 10 V, the supply voltage at least 24 V has to DC , respectively. At low bias voltage of the sensor, no negative output range up to -10 V can be used.
[3]Details: see PCB Declaration of Conformance PS023
included supply
065B01Mounting locknut, 3 / 8-24 threads-1
(M) Metric assembly
included supply
065A42Mounting locknut, M10 x 1.0 thread-1
(S) stainless steel diaphragm
membrane316L (stainless steel)

8 other articles of the same category: