PCB-TLD352M131

PCB-TLD352M131

  • ICP®-Vibrationssensor, 
  • Measuring range ± 50 g pk, 
  • Sensitivity 100 mV / g, 
  • Frequency range 0.5 ... 10.000 Hz, 
  • 10-32 connector at the top, 
  • Ground isolated, 
  • High frequency calibration included

specifications
basic dataEnglish unitsSI units 
Sensitivity (± 10%)100 mV/g10,2 mV/(m/s²)
measuring range± 50 g pk pk±4.90 m/s²pk
Frequency range (± 5%)0,5 … 10.000 Hz
Frequency range (± 10%)0,3 … 14.000 Hz
resonant frequency≥40.000 Hz
Broadband resolution0,00015 g msRMS0,0015 m/s² msRMS[1]
linearity error≤1 %[2]
Lateral acceleration sensitivity≤5 %[3]
Operating conditions
Overload limit (shock)± 5,000 g pk±49.000 m/s²pk
Temperature range (operation)-65 … 250 °F-54 … 121 °C
Strain sensitivity (base area)0.003 g / me0.029 (m / s²) / me[1]
Technical characteristics
supply voltage18 … 30 VDC
Constant current supply2… 20 mA
output impedanceΩ200 Ω
Bias voltage7 … 12 VDC
discharging0,6 … 2,0 s
Spectral noise (1 Hz)39 µg/√Hz380 (µm/s²)/√Hz
Spectral noise (10 Hz)11 µg/√Hz110 (µm/s²)/√Hz[1]
Spectral noise (100 Hz)3,4 µg/√Hz33 (µm/s²)/√Hz[1]
Spectral noise (1,000 Hz)1,4 µg/√Hz14 (µm/s²)/√Hz[1]
Physical properties
Size - height0,93 in23,6 mm
Size - hexagon0,44 in11,2 mm
Mass0,21 oz6.0 grams[1]
sensor elementceramics
Geometry of the sensor elementScherprinzip
housing materialTitan
sealHermetically sealed
Electrical connection10-32 coaxial
port locationAbove
mounting thread10-32 female thread
Montagedrehmoment10 … 20 in-lb113 … 226 Ncm

[4]

Hints
[1]typically,
[2]Zero-based balancing line, determined by the least squares method
[3]The data for temperatures over 121 ° C are only valid for transducers with HT option.
[4]Details: siehe PCB Declaration of Conformance PS023

included supply
080Aadhesive mounting(1)
080A109Montagewachs(1)
081B05Mounting bolts (10-32 to 10-32)(1)
ACS-1Frequency response, traceable to NIST (10 Hz to the upper 5% point)(1)
M081B05Mounting bolts 10-32 to M6 x 0.75(1)

Available options
(HT) High temperature electronics
Frequency range (± 5%)5 … 10.000 Hz
Frequency range (± 10%)3 … 15.000 Hz
temperature range-65 … 325 °F-54 … 163 °C
supply voltage22 … 30 VDC
Spectral noise (1 Hz)200 µg/√Hz1.962 (µm/s²)/√Hz
Spectral noise (10 Hz)30 µg/√Hz294 (µm/s²)/√Hz
Bias voltage10 … 15 VDC
included supply
ACS-68Calibration certificate, traceable to NIST(1)
(J) Mass insulation
Frequency range (± 5%)9.000 Hz
Frequency range (± 10%)14.000 Hz
resonant frequency40.000 Hz
Electrical insulation>100 MΩ
Size - hexagon0,44 in11,2 mm
Size - height0,93 in23,6 mm
Mass0,21 oz6.0 grams
(W) Waterproof cable connection
port locationAbove
(T) TEDS memory according to IEEE PP1451.4
Temperature range (memory access)-10 … 250 °F-23 … 121 °C
supply voltage20 … 30 VDC
Bias voltage7,5 … 13 VDC
(TLA) TEDS LMS International - Free Format
Temperature range (memory access)-10 … 250 °F-23 … 121 °C
supply voltage20 … 30 VDC
Bias voltage7,5 … 13 VDC
(TLB) TEDS LMS International - format for the automotive industry
Temperature range (memory access)-10 … 250 °F-23 … 121 °C
supply voltage20 … 30 VDC
Bias voltage7,5 … 13 VDC
(TLC) TEDS LMS International - format for the aerospace industry
Temperature range (memory access)-10 … 250 °F-23 … 121 °C
supply voltage20 … 30 VDC
Bias voltage7,5 … 13 VDC
(TLD) TEDS memory according to IEEE P1451.4
Temperature range (memory access)-10 … 250 °F-23 … 121 °C
supply voltage20 … 30 VDC
Bias voltage7,5 … 13 VDC

22 other articles of the same category: