PCB-(M)234B
    zoom_out_map

      PCB-(M)234B

      • Force measuring element with charge output,
      • Range 35.6 … 111 kN,
      • Sensitivity 4.05 pC/N,
      • Upper frequency limit 8,000 Hz,
      • 10-32 female connector on the side
      basic data
      Sensitivity (± 15%)18 pC / lb4047 pC / kN
      Measurement range (compression force)≤25.000 lb≤111,2 kN
      Measurement range (tensile force)≤8.000 lb≤35,59 kN
      Maximum static force (compression force)30,000 lb133.45 kN
      Maximum static force (tensile force)10,000 lb44.48 kN
      Upper limit frequency8000 Hz[1] [2]
      linearity error≤1% FS[3]
      Operating conditions
      temperature range-100 ... 400 ° F-73 ... 204 ° C
      Temperature coefficient of sensitivity≤0,03% / ° F≤0,054% / ° C
      Technical characteristics
      capacity≤32 pF[4]
      insulation resistance?1.000.000 MΩ
      physical properties
      rigidity6 lb / microinches1.05 kN / micron[4]
      Size - Diameter1.34 in34.04 mm
      Size - Height2.50 in63.5 mm
      Dimensions8.7 oz246 grams
      housing materialstainless steel
      sealhermetically sealed
      electrical connection10-32 coaxial
      port locationLaterally
      mounting thread5 / 8-18 femaleNo metric equivalent
      Hints
      [1]Assuming a value determined on the basis of solid-state dynamic calculations
      [2]The lower limit frequency and system noise are dependent on the signal conditioning electronics.
      [3]Zero-based line of best fit, determined by the method of least squares
      [4]typically,
      (M) Metric assembly
      mounting threadno equivalentM16 x 1.50 Female
      (P) Positive output polarity
      (W) Waterproof cable connection
      cable outletLaterally
      PCB-(M)234B

      Specific References

      Download

      234B_drawing.PDF

      Technical drawing

      Download (70.74k)

      234B_manual.PDF

      Operating instructions

      Download (1.68M)

      234B_specs.PDF

      Technical data sheet

      Download (22.6k)