PCB-356A67

PCB-356A67

  • Triaxial ICP® vibration sensor,
  • With built-in low-pass filter,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 0.5 … 2,500 Hz,
  • 4-pin female connector on the side
  • of
    basic data
    sensitivity (±10%)10 mV / g1.02 mV/(m/s²)
    range±500 g pk ±4. 900 m/s² pk
    frequency (Y - and Z-axis) (-5%)0.5 … 2,500 Hz[2]
    Frequency range (X-axis) (-5%)0,5 … 3,000 Hz[2]
    resonance frequency≥ 25,000 Hz
    integrated Filterfirst order
    edge steepness of the filter6 dB/octave
    electric filter corner frequency10,000 Hz[3]
    wide band resolution0.0005 g RMS0.005 m/s² RMS[1]
    Linearity error (400 g, 3.920 m/s²)≤ 1%[3]
    linearity error (500 g, 4,900 m/s²)≤ 2%[3]
    Transverse acceleration sensitivity≤ 5%
    Conditions of use
    Overload limit (shock)±7. 000 g pk±68. 600 m/s² PK
    Temperature range (operation)-65 … 250 ° F-54 … 121 ° C
    strain sensitivity (base area)0.001 g/µε0.01 (m/s²)/µε[1]
    specifications
    power supply20 … 30 V DC
    Constant power supply2 … 20 mA
    output impedance≤200Ω
    Bias voltage8 … 12 V DC
    discharging charging time constant1.0 … 2.0 s
    Settling time < br(auf Bias-Spannung ±10 %)<5 s
    spectral noise (1 Hz)150 µg / √ Hz1,472 (µm / s ²) / √ Hz[1]
    Spectral noise (10 Hz)25 µg / √ Hz245 (µm / s ²) / √ Hz[1]
    Spectral noise (100 Hz)10 µg / √ Hz98 (µm / s ²) / √ Hz[1]
    spectral noise (1,000 Hz)5 µg / √ Hz49 ( µm / s ²) / √ Hz[1]
    physical properties
    sensor elementceramic
    geometry of the sensor elementshear principle
    Housing materialtitanium
    sealinghermetically sealed
    size e height0.55 in14.0 mm
    size - length0.80 in20.3 mm
    size - width0.55 in14.0 mm
    mass0.37 oz10.5 grams[1]
    wiring1/4 "-28 4-pin
    " Connecting positionside
    mounting thread10-32 female thread
    Assembly torque10 … 20 in-lb113 … 225 NCM
    notes
    [1]typically
    [2]The upper cut-off frequency tolerance: ±500 Hz
    [3]zero-based balancing line, determined using the method of least squares
    [4]Details: see PCBs Declaration of conformance PS023
    Equipment
    080A109mounting wax-1
    080A12Adhesive mounting-1
    081 B 05mounting bolts (10-32 on 10-32)-1
    ACS-1 T Frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency-1
    M081B05mounting bolts 10-32 to M6 x 0.75-1