PCB-(M)102B04
    zoom_out_map

      PCB-(M)102B04

    • ICP® pressure sensor with INVAR-membrane,
    • Masseisoliert,
    • Beschleunigungskompensiert,
    • Measuring range 6,900 kPa,
    • Sensitivity 0.7 mV / kPa,
    • Lower limiting frequency 0.005 Hz,
    • 10-32 female connector
    •  

      basic data
      measuring range (±5 V output range)1,000 psi6,900 kPa 
       
      usable range (output range ±10 V)2,000 psi13.790 kPa[1]
       
      sensitivity (±10%)5.0 mV / psi0.7 mV / kPa 
       
      maximum static pressure10,000 psi69,000 kPa 
       
      Resolution0,02 psi0.14 kPa[2]
       
      resonance frequency≥ 500, 000 Hz  
       
      Rise time (reflected pressure)≤ 1.0 µs  
       
      lower limiting frequency (-5%)0.005 Hz  
       
      linearity error≤1.0% FS [3]
      conditions
      acceleration sensitivity≤ 0.002 psi/g≤ 0,0014 kPa/(m/s²) 
       
      temperature range ( Operation)-100 … 275 ° F-73 … 135 ° C 
       
      Temperature coefficient of sensitivity≤ 0.03 %/°F≤ 0,054 %/°C[2]
       
      maximum temperature shock(for fraction of a second)3,000 ° F1,650 ° C 
       
      Maximum shock resistance20,000 g pk196.140 m/s² pk 
      Technical characteristics
      Output polarity (positive pressure)positive  
       
      Discharging charging time constant (at room temperature)≤100 Ω  
       
      supply20 … 30 V DC  
       
      Constant power supply2 … 20 mA  
       
      output impedance< 100Ω  
       
      Bias voltage8 … 14 V DC  
       
      electrical insulation100 MΩ 
      -physical Properties
      geometry of the sensor elementcompression principle  
       
      sensor elementquartz  
       
      parts usematerialstainless steel  
       
      membraneINVAR  
       
      sealedsealeddensely welded  
       
      electrical connection10-32-coaxial socket  
       
      mass0.41 oz11.6 grams 
      Notes
      [1]for output range supply voltage up to 10 V must be at least 24 V DC. At low bias voltage of the sensor, no negative output range is usable up to-10 V.  
       
      [2]typically  
       
      [3]zero-based balancing line, determined using the method of least squares  
       
      [4]details: see PCBs Declaration of conformance PS023  
      equipment
      065A03sealing ring, 0.435 "outside x 0,377" x 0.030 "high brass3 
      (M) metric mounting
      equipment   
       
      065A40sealing ring, 0.435" outside x 0,397 "x 0.030" high brass3 
      (S) stainless steel diaphragm
          
      PCB-(M)102B04

      Specific References

      Download

      102B04_drawing.PDF

      Technical drawing

      Download (431.51k)

      102B04_manual.PDF

      Operating instructions

      Download (779.65k)

      102B04_specs.PDF

      Technical data sheet

      Download (254.36k)