PCB-MXM622A11
    zoom_out_map

      PCB-MXM622A11

    • Industrial ICP® vibration sensor,
    • With mining approval
    • Measurement range 50 g,
    • Sensitivity 100 mV/g,
    • Frequency range 0.2 … 10,000 Hz,
    • Frequency response calibration,
    • Integrated cable, length 3 m,
      ending on cut end
    • "
      basic data
      sensitivity (±5%)100 mV/g10.2 mV/(m/s²)[4]
      measuring range±50 g±490 m / s²
      Frequency range (±5%)35 … 240,000 cpm0.58 … 4,000 Hz[5]
      frequency range (± 10%)25 … 300,000 cpm0,42 … 5,000 Hz
      frequency range (± 3 dB)12 … 600,000 cpm0.2 … 10,000 Hz
      resonance frequency1.200 kcpm20,000 Hz[3]
      wide band resolution50 µg490 µm / s ²[3]
      linearity≤1%[6]
      Transverse acceleration sensitivity≤ 5%
      conditions of use
      Overload limit (shock)5,000 g pk 49,050 m/s² pk
      temperature range-65 … 250 ° F-54 … 121 ° C
      ProtectionIP68
      mine approvalI M1 EX iA I
      technical characteristics
      settling time (on bias voltage ± 1%) ≤ 5.0 s
      discharging charging time constant≥ 0.8 s
      power18 … 28 V DC
      Constant power supply2 … 20 mA
      output impedance< 100 Ω
      Bias voltage8 … 12 V DC
      spectral noise (10 Hz)4.0 µg / √ Hz39.2 (µm / s ²) / √ Hz[3]
      spectral noise (100 Hz)0.8 µg / √ Hz7.85 (µm / s ²) / √ Hz[3]
      spectral noise (1,000 Hz)0.4 µg / √ Hz3.9 (µm / s ²) / √ Hz[3]
      electrical protectionRFI/ESD
      electrical insulation≥ 100 MΩ
      Physical properties
      Size - hex7/8 in22 mm
      Size - height4.3 in109 mm
      dimensions (without cable)3.3 oz94 grams
      mounting thread1 / 4 "-28 threadedno equivalent[1]
      Assembly torque2 … 5 ft-lb2.7 … 6.8 Nm
      sensor elementceramics"
      Geometry of the sensor elementshear principle
      housing materialstainless steel
      Sealinghermetically sealed welded
      Cable length10 ft3.0 m
      cable typepolyurethane[2]
      notes
      [1]No Ä equivalent in SI units
      [2]Screened two-wire cable with twisted wire
      [3]typically
      [4]conversion factor 1 g= 9.81 m/s²
      [5]the upper cut-off frequency tolerance: ±10%
      [6]zero-based balancing line, determined with the method the least squares
      [7]details: see PCBs Declaration of conformance PS023, PS090 and < a href = ""... "/ produkte_skript/downloads/ce/ps061.pdf" "class ="blue"> PS061
      equipment
      M081A61metric mounting bolts with M6 thread-1
      ICS-1frequency response for uniaxial sensors from 10 Hz up to the upper 5% frequency-1
      PCB-MXM622A11

      Specific References

      Download

      MXM622A11_drawing.PDF

      Technical drawing

      Download (33.11k)

      MXM622A11_manual.PDF

      Operating instructions

      Download (1.39M)

      MXM622A11_specs.PDF

      Technical data sheet

      Download (535.05k)