PCB-482C24
basic data | |||
number channels | 4 | ||
sensor types | ICP, voltage <! –
| ||
Voltage gain | 0.1 … 200x | ||
accuracy < br(Verstärkungsfaktor 0,1x … 0,4x) | ≤5% | ||
Accuracy < br(Verstärkungsfaktor 0,5x … 200X) | ≤1% | ||
output range | ±10 V | ||
Frequency range (-5%) < br(Verstärkungsfaktor 0,1x … 99,9x) | 0.05 … 100,000 Hz | [1] | |
frequency range (-5%) < br(Verstärkungsfaktor 100x … 200X) | 0.05 … 50,000 Hz | ||
maximum phase error | ±1 ° | ||
crosstalk | -72 dB | ||
TEDS support | Yes | ||
bias voltage/error display | Open circuit/short circuit/overload | ||
Manual | |||
Control | keypad | ||
Digital display | 2 lines, 16 characters | ||
digital interface | |||
interface | |||
Data rates | 19.200 bps | ||
Start, stop, parity | 1, 8, 1, no | ||
hand shake | RTS/CTS | ||
Cable length (max) | 50 ft | 15.2 m | |
conditions of use | |||
temperature range | 32 … 120 ° F | 0 … 50 ° C | |
Technical characteristics | |||
power supply < br(für mitgeliefertes Netzteil) | AC | ||
mains voltage (50 … 60 Hz) | 100 … 240 VAC | ||
power consumption (power supply unit) | ≤1.6 A | ||
Spannungsversorgung (sensor-Versorgungseinheit) | DC | ||
Spannungsversorgung (sensor-Versorgungseinheit) | 9 … 18 V DC | ||
Stromaufnahme (sensor-Versorgungseinheit) | ≤2.5 A | ||
supply voltage (for sensor) | 24 V DC | ||
Constant power supply (for sensor) | 0 … 20 mA | [2] | |
Overload threshold (±0. 2 V pk) | 10 V PK | ||
DC offset (AC coupled) | ≤50 mV | ||
DC offset (DC coupled, amplification factor 0, 1 x … 99, 9 x) | < 10 mV | ||
DC offset (DC coupled, gain 100x … 200x) | < 20 mV | ||
output impedance | ≤50Ω | ||
"clamped output" option | enabled by default | [4] | |
wide band noise (1 … 10,000 Hz) (amplification factor 1 x) | 50.0 µV rms | [3] | |
spectral noise (1 Hz) (amplification factor 1 x) | 8.0 µV / √Hz | [3] | |
spectral noise (10 Hz) (amplification factor 1 x) | 1.5 µV / √Hz | [3] | |
spectral noise (100 Hz) (amplification factor 1 x) | 1.0 µV / √Hz | [3] | |
Spectral noise (1,000 Hz) (amplification factor 1 x) | 1.0 µV / √Hz | [3] | |
spectral noise (10,000 Hz) (amplification factor 1 x) | 1.0 µV /√Hz | [3] | |
wide band noise (1 … 10,000 Hz) (amplification factor x 10) | 75.0 µV rms | [3] | |
spectral noise (1 Hz) (amp ärkungsfaktor 10 x) | 20.0 µV / √Hz | [3] | |
spectral noise (10 Hz) (amplification factor x 10) | 1.5 µV / √Hz | [3] | |
Spectral noise (100 Hz) (amplification factor x 10) | 1.0 µV / √Hz | [3] | |
spectral noise (1,000 Hz) (amplification factor x 10) | 1.0 µV / √Hz | [3] | |
spectral noise (10,000 Hz) (amplification factor x 10) | 1.0 µV / √Hz | [3] | |
wide band noise (1 … 10,000 Hz) ( Amplification factor100 x) | 350 µV rms | [3] | |
spectral noise (1 Hz) (gain 100 x) | 100,0 µV / √Hz | [3] | |
spectral Noise (10 Hz) (gain 100 x) | 10.0 µV / √Hz | [3] | |
spectral noise (100 Hz) (gain 100 x) | 8.0 µV / √Hz | [3] | |
Spectral noise (1,000 Hz) (gain 100 x) | 6.0 µV / √Hz | [3] | |
spectral noise (10,000 Hz) (100 x gain) | 6.0 µV / √Hz | [3] | |
physical properties | |||
electrical connection (sensor input) | BNC Jack | ||
electric Connection (output) | BNC socket | ||
electrical connection (DC power supply) | 6-pin mini DIN socket | ||
electric Anschluss (RS-232-Digitalschnittstelle) | DB-9 connector | ||
size - height | 3.2 in | 8.1 cm | |
size -. Wide | 8.0 in | 20 cm | |
Size - deep | 5.9 in | 15 cm | |
mass | 2.00 lb | 908 grams | |
notes | |||
[1] | 0 Hz @ DC coupled | ||
[2] | configurable, default setting at the factory: 4 mA (±1. 0 mA). The channels can individually be configured. | ||
[3] | typically with AC coupling | ||
[4] | see operating instructions | ||
[5] | Details: see PCBs Declaration of conformance PS024 | ||
equipment | |||
017AXX | power cord | -1 | |
100-7103-50 | connection cable, length 1.8 metres, 9-pin male to 9-pin female- | -1 | |
488 B 14/NC | power supply | -1 | |
EE75 | Configuration software "MCSC" | -1 |