Piezoelectric strain sensors measure dynamic and quasistatic stresses on machines. Either glued on or mounted on the surface of a machine or structure by means of a mounting screw, the sensors measure minute strains. On the examinee itself, no changes must be made. Due to the internal ICP® amplifier, the operation of these sensors is possible on...

Piezoelectric strain sensors measure dynamic and quasistatic stresses on machines. Either glued on or mounted on the surface of a machine or structure by means of a mounting screw, the sensors measure minute strains. On the examinee itself, no changes must be made. Due to the internal ICP® amplifier, the operation of these sensors is possible on all standard supply units.

More

Strain sensors  There are 7 items.

per page
Show 1 - 6 of 7 articles
  • ICP® strain sensor, Measuring range 100 µ ε Sensitivity 50mv / µ ε Frequency range 0.5 … 100,000 Hz, Integrated cable, length 3 m, ending on 10-32 plug ICP® strain sensor, Measuring range 100 µ ε Sensitivity 50mv / µ ε Frequency range 0.5 … 100,000 Hz, Integrated cable, length 3 m, ending on 10-32 plug

  • ICP® strain sensor,  Measuring range 900 με,  Sensitivity 5 mV / με,  Frequency range 0.5 ... 100,000 Hz,  Integrated connection cable, length 3 meters,ending on 10-32 plug ICP® strain sensor,  Measuring range 900 με,  Sensitivity 5 mV / με,  Frequency range 0.5 ... 100,000 Hz,  Integrated connection cable, length 3 meters,ending on 10-32 plug

  • ICP® strain sensor,  Measuring range 900 με,  Sensitivity 2 pC / με,  Frequency range 0.5 ... 100,000 Hz,  Integrated connection cable, length 3 meters,ending on 10-32 plug ICP® strain sensor,  Measuring range 900 με,  Sensitivity 2 pC / με,  Frequency range 0.5 ... 100,000 Hz,  Integrated connection cable, length 3 meters,ending on 10-32 plug

  • ICP® strain sensor,  Measuring range 300 με,  Sensitivity 10 mV / με,  Lower limit frequency 0.004 Hz,  10-32 connector on the side,  Masseisolierung ICP® strain sensor,  Measuring range 300 με,  Sensitivity 10 mV / με,  Lower limit frequency 0.004 Hz,  10-32 connector on the side,  Masseisolierung

  • ICP® strain sensor, Measurement range 50 µ ε Sensitivity 100 mV / µε Lower limiting frequency 0.015 Hz, 10-32 female connector on the side ICP® strain sensor, Measurement range 50 µ ε Sensitivity 100 mV / µε Lower limiting frequency 0.015 Hz, 10-32 female connector on the side

  • ICP® strain sensor, Measuring range 100 µ ε Sensitivity 50mv / µ ε Lower limiting frequency 0.004 Hz, 10-32 female connector on the side ICP® strain sensor, Measuring range 100 µ ε Sensitivity 50mv / µ ε Lower limiting frequency 0.004 Hz, 10-32 female connector on the side